Fast Verification of Gamma Knifetrade Mark Treatment Plans

Overview
Date 2001 Oct 25
PMID 11674832
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

The Leksell stereotactic Gamma Knifetrade mark uses radiation from 201 (60)Co sources that are focused to the center of a collimator helmet to deliver a high dose of radiation with minimal irradiation of proximal structures. This paper presents a method for fast verification of the irradiation time as calculated by the Leksell Gamma Knifetrade mark treatment planning software GammaPlan((R)). To obtain the irradiation time for each shot in the treatment plan, one must first accurately calculate the tissue maximum ratio (TMR) for each of the individual 201 beams. The algorithm presented in this paper begins with the determination of the geometrical relationship between the Gamma Knifetrade mark collimator helmet and the stereotactic frame. A group of reference points is measured to build a head model simulating the patient skull geometry. During radiosurgery, the isocenter of the collimator helmet is moved to the shot center. A group of spatial vectors describing the reference points at the skull surface is obtained by converting the Cartesian coordinates to Polar coordinates. For each individual beam, the three nearest reference vectors are found by ranking the relative angles. The depth that each beam penetrates the patient's skull to the isocenter is obtained via linear interpolation. The TMR for each beam then is compared with the TMR for the calibration setup, which is done using a spherical 8 cm radius phantom. This algorithm is applied to verify the treatment time calculated in GammaPlan((R)) Version 5.2. The results are shown to agree with GammaPlan((R)) within 3%.

Citing Articles

Validation of Gamma Knife Perfexion Dose Profile Distribution by a Modified Variable Ellipsoid Modeling Technique.

Hur B, Jin S, Kim G, Kwak J, Kim Y, Lee S J Korean Neurosurg Soc. 2021; 64(1):13-22.

PMID: 33465847 PMC: 7819799. DOI: 10.3340/jkns.2020.0186.


Evaluation of a new secondary dose calculation software for Gamma Knife radiosurgery.

Prusator M, Zhao T, Kavanaugh J, Santanam L, Dise J, Goddu S J Appl Clin Med Phys. 2020; 21(1):95-102.

PMID: 31943756 PMC: 6964756. DOI: 10.1002/acm2.12794.


Development and validation of a comprehensive patient-specific quality assurance program for a novel stereotactic radiation delivery system for breast lesions.

Becker S, Niu Y, Mutaf Y, Chen S, Poirier Y, Nichols E J Appl Clin Med Phys. 2019; 20(12):138-148.

PMID: 31833640 PMC: 6909122. DOI: 10.1002/acm2.12778.


Two-year experience with the commercial Gamma Knife Check software.

Xu A, Bhatnagar J, Bednarz G, Novotny Jr J, Flickinger J, Lunsford L J Appl Clin Med Phys. 2016; 17(4):95-105.

PMID: 27455470 PMC: 5690029. DOI: 10.1120/jacmp.v17i4.5547.


Effect of skull contours on dose calculations in Gamma Knife Perfexion stereotactic radiosurgery.

Nakazawa H, Komori M, Mori Y, Hagiwara M, Shibamoto Y, Tsugawa T J Appl Clin Med Phys. 2014; 15(2):4603.

PMID: 24710447 PMC: 5875478. DOI: 10.1120/jacmp.v15i2.4603.


References
1.
Kondziolka D, Dempsey P, Lunsford L, Kestle J, Dolan E, Kanal E . A comparison between magnetic resonance imaging and computed tomography for stereotactic coordinate determination. Neurosurgery. 1992; 30(3):402-6; discussion 406-7. DOI: 10.1227/00006123-199203000-00015. View

2.
Wu A, Lindner G, Maitz A, Kalend A, Lunsford L, Flickinger J . Physics of gamma knife approach on convergent beams in stereotactic radiosurgery. Int J Radiat Oncol Biol Phys. 1990; 18(4):941-9. DOI: 10.1016/0360-3016(90)90421-f. View

3.
Walton L, BOMFORD C, Ramsden D . The Sheffield stereotactic radiosurgery unit: physical characteristics and principles of operation. Br J Radiol. 1987; 60(717):897-906. DOI: 10.1259/0007-1285-60-717-897. View