Relation Between Heart Rate and Pulse Transit Time During Paced Respiration

Overview
Journal Physiol Meas
Date 2001 Sep 15
PMID 11556663
Citations 29
Authors
Affiliations
Soon will be listed here.
Abstract

Pulse transit time (PTT) is a simple, non-invasive measurement, defined as the time taken from a reference time for the pulse pressure wave to travel to the periphery. PTT is influenced by heart rate, blood pressure changes and the compliance of the arteries, but few quantitative data are available describing the factors which influence PTT. The aim of this study was to investigate the relationship between the cardiac beat-to-beat interval (RR) and PTT, using paced respiration to generate changes in both variables. We analysed PTT and RR interval from 15 normal healthy subjects during paced breathing, and the cross-correlation function between PTT and RR was used to quantify their relationship. Over the 15 subjects, the maximum change in PTT ranged from 7 to 23 ms with a mean +/- standard deviation of 14 +/- 5 ms, and that in RR interval from 86 to 443 ms (241 +/- 102 ms). Examining changes over time, the best correlation (r = +0.69, p < 0.01) was obtained when PTT was advanced relative to RR, with a change in RR followed by a corresponding change in PTT 3.17 +/- 0.76 beats later. We conclude that there is a strong relationship between PTT changes and RR interval changes, but these changes are not in phase.

Citing Articles

History and evolution of blood pressure measurement.

Noh S, Kim H, Kang S, Yoon C, Youn T, Chae I Clin Hypertens. 2024; 30(1):9.

PMID: 38556854 PMC: 10983645. DOI: 10.1186/s40885-024-00268-7.


Nonlinear model-based cardiac arrhythmia diagnosis using the optimization-based inverse problem solution.

Gholami M, Maleki M, Amirkhani S, Chaibakhsh A Biomed Eng Lett. 2022; 12(2):205-215.

PMID: 35529347 PMC: 9046521. DOI: 10.1007/s13534-022-00223-1.


A Novel Redundant Validation IoT System for Affective Learning Based on Facial Expressions and Biological Signals.

Marceddu A, Pugliese L, Sini J, Espinosa G, Amel Solouki M, Chiavassa P Sensors (Basel). 2022; 22(7).

PMID: 35408387 PMC: 9003217. DOI: 10.3390/s22072773.


Coordination between heart rate variability and physical activity may be diminished by fatigability in non-older women in the hour before sleep.

Taniguchi K, Shimouchi A, Jinno N, Seiyama A Physiol Rep. 2021; 9(22):e15126.

PMID: 34826217 PMC: 8624186. DOI: 10.14814/phy2.15126.


Cross-instrument feasibility, validity, and reproducibility of wireless heart rate monitors: Novel opportunities for extended daily life monitoring.

Kunkels Y, van Roon A, Wichers M, Riese H Psychophysiology. 2021; 58(10):e13898.

PMID: 34286857 PMC: 10138748. DOI: 10.1111/psyp.13898.