» Articles » PMID: 11554422

Method for Confirmation of Synthetic Corticosteroids in Doping Urine Samples by Liquid Chromatography-electrospray Ionisation Mass Spectrometry

Overview
Journal J Chromatogr A
Publisher Elsevier
Specialty Chemistry
Date 2001 Sep 14
PMID 11554422
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

In this study, we report on the development of a method to confirm simultaneously nine of the most commonly abused synthetic corticosteroids in urine based on liquid chromatography-electrospray ionisation mass spectrometry. A considerable simplified sample preparation procedure, including liquid-liquid phase extraction with Extrelut-NT3 columns, provided both excellent sample purification and high overall recoveries. Complete HPLC separations were obtained on a reversed-phase column with 1 mM ammonium acetate-acetonitrile (60:40, v/v) as mobile phase. Mass spectral acquisition was done in the negative ion, and selected ion monitoring modes to identify the drugs with at least three characteristic ions. Detection limits were determined at < or =1 ng/ml and the confirmation limits at 1 to 5 ng/ml.

Citing Articles

Simultaneous analysis of 44 frequently abused corticosteroid drugs using polysaccharide-based chiral column-HRMS approach.

Karakka Kal A, Karatt T, Nalakath J, Subhahar M, Koshy S, Perwad Z Anal Sci Adv. 2024; 2(9-10):427-439.

PMID: 38716441 PMC: 10989529. DOI: 10.1002/ansa.202000166.


Amin-modified graphene oxide as a promising adsorbent for selective extraction of dexamethasone adulterant from herbal supplements.

Nemati M, Zayer A, Hamidi S Turk J Chem. 2023; 46(5):1744-1754.

PMID: 37529734 PMC: 10390148. DOI: 10.55730/1300-0527.3477.


Classical versus chemometrics tools for spectrophotometric determination of fluocinolone acetonide, ciprofloxacin HCl and ciprofloxacin impurity-A in their ternary mixture.

Tantawy M, Wahba I, Saad S, Ramadan N BMC Chem. 2023; 17(1):49.

PMID: 37287045 PMC: 10249224. DOI: 10.1186/s13065-023-00963-w.


Determination of Endocrine Disrupting Chemicals in Water and Wastewater Samples by Liquid Chromatography-Negative Ion Electrospray Ionization-Tandem Mass Spectrometry.

Aborkhees G, Raina-Fulton R, Thirunavokkarasu O Molecules. 2020; 25(17).

PMID: 32867135 PMC: 7503312. DOI: 10.3390/molecules25173906.


Fingerprint Spectrophotometric Methods for the Determination of Co-Formulated Otic Solution of Ciprofloxacin and Fluocinolone Acetonide in Their Challengeable Ratio.

Obaydo R, Sakur A J Anal Methods Chem. 2019; 2019:8919345.

PMID: 31612094 PMC: 6758403. DOI: 10.1155/2019/8919345.