Real-time Optical Coherence Tomography of the Anterior Segment at 1310 Nm

Overview
Journal Arch Ophthalmol
Specialty Ophthalmology
Date 2001 Aug 14
PMID 11483086
Citations 137
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Recent advances in high-speed scanning technology have enabled a new generation of optical coherence tomographic (OCT) systems to perform imaging at video rate. Here, a handheld OCT probe capable of imaging the anterior segment of the eye at high frame rates is demonstrated for the first time.

Objective: To demonstrate real-time OCT imaging of anterior segment structures.

Design: Survey of anterior segment structures in normal human subjects.

Setting: Laboratory.

Main Outcome Measures: Achieving real-time imaging of the anterior segment, satisfactory image quality, and convenience of a handheld probe.

Results: Optical coherence tomographic imaging of the anterior segment of the eyes of human subjects was performed using 1310-nm wavelength light with an image rate of 8 frames per second. Imaging trials demonstrated clear resolution of corneal epithelium and stroma, sclerocorneal junction, sclera, iris pigment epithelium and stroma, and anterior lens capsule. The anterior chamber angle was clearly visualized. Limited imaging of the ciliary body was performed. Real-time imaging of pupillary constriction in response to light stimulus was also performed.

Conclusion: High-speed OCT at 1310-nm wavelength is a potentially useful technique for noninvasive assessment of anterior segment structures.

Clinical Relevance: Our results suggest that real-time OCT has potential applications in glaucoma evaluation and refractive surgery.

Citing Articles

The role of anterior segment optical coherence tomography in post-cataract surgery Descemet membrane detachment.

Ruggeri F, Rullo D, Maugliani E, Trotta N, Ciancimino C, Di Pippo M Int Ophthalmol. 2025; 45(1):74.

PMID: 39964581 PMC: 11836178. DOI: 10.1007/s10792-024-03397-y.


Repeatability and reproducibility of a new spectral-domain optical coherence tomography biometer and agreement with swept-source optical coherence tomography based biometer.

Li X, Lei C, Ning R, Liu L, Chen A, Yang X Eye Vis (Lond). 2025; 12(1):6.

PMID: 39891211 PMC: 11786401. DOI: 10.1186/s40662-024-00422-0.


Loss values of style transfer from UBM to AS-OCT images for plateau iris classification.

Kaothanthong N, Wanichwecharungruang B, Chantangphol P, Pattanapongpaiboon W, Theeramunkong T Sci Rep. 2024; 14(1):31157.

PMID: 39732818 PMC: 11682431. DOI: 10.1038/s41598-024-82327-5.


Optical clearing with tartrazine enables deep transscleral imaging with optical coherence tomography.

Narawane A, Trout R, Viehland C, Kuo A, Vajzovic L, Dhalla A J Biomed Opt. 2024; 29(12):120501.

PMID: 39669907 PMC: 11635458. DOI: 10.1117/1.JBO.29.12.120501.


Robust and accurate corneal interfaces segmentation in 2D and 3D OCT images.

Zhu X, Huang W, Ma S, Yi Q Front Med (Lausanne). 2024; 11:1381758.

PMID: 38562374 PMC: 10982348. DOI: 10.3389/fmed.2024.1381758.