Corneal Hydration Affects Ablation During Laser in Situ Keratomileusis Surgery

Overview
Journal Cornea
Specialty Ophthalmology
Date 2001 May 3
PMID 11333327
Citations 21
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Studies in animal eyes indicate that the level of corneal hydration affects the ablation rate of laser surgery; the greater the hydration is, the less the ablation for a given laser pulse. Our study is an assessment in human eyes comparing the effects on ablation by blotting the corneal stromal surface under a corneal flap created for laser in situ keratomileusis (LASIK) procedures between sets of excimer laser pulses, with ablation depth in eyes not blotted between sets of laser pulses.

Methods: We modified the surgical technique for LASIK procedures to assess the effects of the level of hydration on excimer laser ablation depth per pulse. In group 1, 40 eyes underwent LASIK surgery without any modification. Group 2 was composed of 36 eyes having LASIK procedures, but the corneal surfaces were kept relatively dry by blotting of the stromal surface between sets of laser pulses.

Results: Six months after surgery, the mean spherical equivalent refractive change was from -8.38 diopters (D) to -1.44 D in group 1 and from -7.93 D to -0.09 D in group 2. For predictability, the deviation from the target refraction after surgery was assessed. Thirty-three percent (13 of 40) in group 1 and 25% (9 of 36) in group 2 were within +/-0.5 D. Forty-eight percent (19 of 40) in group 1 and 50% (18 of 36) in group 2 were within +/-1 D. Six months after surgery, 80% or more in both groups were within +/-2 D. There was myopic regression in all patients. Three months after surgery, regression averaged -0.71 D in group 1 and -1.15 D in group 2.

Conclusions: Corneal hydration levels affect the efficiency of laser ablation in LASIK procedures. With less hydrated corneas, ablation effects were greater than for corneas not blotted during the procedure, but these patients appear to undergo greater myopic regression.

Citing Articles

Intraoperative Assessment of the Stromal Ablation in Photorefractive Keratectomy.

Barequet D, Levinger E, Levinger N, Levinger S, Barequet I J Clin Med. 2024; 13(7).

PMID: 38610665 PMC: 11012371. DOI: 10.3390/jcm13071901.


Cross Sectional Analysis of Impact of Seasonal Changes on Excimer Laser Ablation Performance on Polymethyl Methacrylate (PMMA).

Verma S, Hesser J, Arba Mosquera S Vision (Basel). 2023; 7(3).

PMID: 37489329 PMC: 10366815. DOI: 10.3390/vision7030050.


One-Year Results of Photorefractive Keratectomy for Myopia and Compound Myopic Astigmatism with 210 nm Wavelength All Solid-State Laser for Refractive Surgery.

Roszkowska A, Tumminello G, Licitra C, Severo A, Inferrera L, Camellin U J Clin Med. 2023; 12(13).

PMID: 37445353 PMC: 10342780. DOI: 10.3390/jcm12134311.


First Clinical Results of a New Generation of Ablative Solid-State Lasers.

Pajic B, Pajic-Eggspuehler B, Cvejic Z, Rathjen C, Ruff V J Clin Med. 2023; 12(2).

PMID: 36675659 PMC: 9860716. DOI: 10.3390/jcm12020731.


Corneal stromal dehydration and optimal stromal exposure time during corneal refractive surgery measured using a three-dimensional optical profiler.

Wu Y, Wang Y, Zhang Z, Yu X Graefes Arch Clin Exp Ophthalmol. 2022; 260(12):4005-4013.

PMID: 35876884 DOI: 10.1007/s00417-022-05764-w.