Electrical Impedance Tomography of Human Brain Activity with a Two-dimensional Ring of Scalp Electrodes

Overview
Journal Physiol Meas
Date 2001 Mar 10
PMID 11236877
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

Previously, electrical impedance tomography (EIT) has been used to image impedance decreases in the exposed cortex of rabbits during brain activity. These are due to increased blood volume at the site of the stimulated cortex; as blood has a lower impedance than brain, the impedance decreases. During human brain activity similar blood flow changes have been detected using positron emission tomography (PET) and functional magnetic resonance imaging (fMRI). If blood volume also changes then the impedance of human cortex will change during brain activity; this could theoretically be imaged with EIT. EIT data were recorded from a ring of 16 scalp electrodes in 34 recordings in 19 adult volunteers before, during and after stimulation with (1) a visual stimulus produced by an 8 Hz oscillating checkerboard pattern or (2) sensory stimulation of the median nerve at the wrist by a 3 Hz electrical square wave stimulus. Reproducible impedance changes, with a similar timecourse to the stimulus, were seen in all experiments. Significant impedance changes were seen in 21 +/- 5% (n = 16, mean +/- SEM) and 19 +/- 3% (n = 18) of the electrode measurements for visual and somatosensory paradigms respectively. The reconstructed 2D EIT images showed reproducible impedance changes in the approximate region of the stimulated cortex in 7/16 visual and 5/18 somatosensory experiments. This demonstrates that reproducible impedance changes can be measured during human brain activity. The final images contained spatial noise; the reasons for this and strategies to reduce this in future are discussed.

Citing Articles

Applications of Electrical Impedance Tomography in Neurology.

Mirhoseini M, Rezanejad Gatabi Z, Das S, Joveini S, Gatabi I Basic Clin Neurosci. 2023; 13(5):595-608.

PMID: 37313030 PMC: 10258591. DOI: 10.32598/bcn.2021.3087.1.


Advances in electrical impedance tomography-based brain imaging.

Ke X, Hou W, Huang Q, Hou X, Bao X, Kong W Mil Med Res. 2022; 9(1):10.

PMID: 35227324 PMC: 8883715. DOI: 10.1186/s40779-022-00370-7.


Stroke damage detection using classification trees on electrical bioimpedance cerebral spectroscopy measurements.

Atefi S, Seoane F, Thorlin T, Lindecrantz K Sensors (Basel). 2013; 13(8):10074-86.

PMID: 23966181 PMC: 3812594. DOI: 10.3390/s130810074.


Wavelet-based artifact identification and separation technique for EEG signals during galvanic vestibular stimulation.

Adib M, Cretu E Comput Math Methods Med. 2013; 2013:167069.

PMID: 23956786 PMC: 3728758. DOI: 10.1155/2013/167069.


Intracranial electrical impedance tomography: a method of continuous monitoring in an animal model of head trauma.

Manwaring P, Moodie K, Hartov A, Manwaring K, Halter R Anesth Analg. 2013; 117(4):866-875.

PMID: 23842194 PMC: 3783592. DOI: 10.1213/ANE.0b013e318290c7b7.