» Articles » PMID: 11094815

Thermal--electrical Finite Element Modelling for Radio Frequency Cardiac Ablation: Effects of Changes in Myocardial Properties

Overview
Publisher Springer
Date 2000 Nov 30
PMID 11094815
Citations 22
Authors
Affiliations
Soon will be listed here.
Abstract

Finite element (FE) analysis has been utilised as a numerical tool to determine the temperature distribution in studies of radio frequency (RF) cardiac ablation. However, none of the previous FE analyses clarified such computational aspects as software requirements, computation time or convergence test. In addition, myocardial properties included in the previous models vary greatly. A process of FE modelling of a system that included blood, myocardium, and an ablation catheter with a thermistor embedded at the tip is described. The bio-heat equation is solved to determine the temperature distribution in myocardium using a commercial software application (ABAQUS). A Cauchy convergence test (epsilon = 0.1 degree C) was performed and it is concluded that the optimal number of elements for the proposed system is 24610. The effects of changes in myocardial properties (+/- 50% electric conductivity, +100%/-50% thermal conductivity, and +100%/-50% specific heat capacity) in both power-controlled (PCRFA) and temperature-controlled RF ablation (TCRFA) were studied. Changes in myocardial properties affect the results of the FE analyses of PCRFA more than those of TCRFA, and the maximum changes in lesion volumes were -58.6% (-50% electric conductivity), -60.7% (+100% thermal conductivity), and +43.2% (-50% specific heat).

Citing Articles

Computer simulations of an irrigated radiofrequency cardiac ablation catheter and experimental validation by infrared imaging.

Rossmann C, Motamarry A, Panescu D, Haemmerich D Int J Hyperthermia. 2021; 38(1):1149-1163.

PMID: 34376106 PMC: 9639669. DOI: 10.1080/02656736.2021.1961027.


High-power, Short-duration Radiofrequency Ablation for the Treatment of AF.

Kotadia I, Williams S, ONeill M Arrhythm Electrophysiol Rev. 2020; 8(4):265-272.

PMID: 32685157 PMC: 7358956. DOI: 10.15420/aer.2019.09.


Design of a stimulation protocol to predict temperature distribution in subcutaneous tissue using the finite element model.

Myoung H, Kim D, Kim H, Lee K Biomed Eng Lett. 2019; 7(3):261-266.

PMID: 30603174 PMC: 6208504. DOI: 10.1007/s13534-017-0029-0.


Lesion modeling, characterization, and visualization for image-guided cardiac ablation therapy monitoring.

Linte C, Camp J, Rettmann M, Haemmerich D, Aktas M, Huang D J Med Imaging (Bellingham). 2018; 5(2):021218.

PMID: 29531966 PMC: 5831757. DOI: 10.1117/1.JMI.5.2.021218.


Mini Electrodes on Ablation Catheters: Valuable Addition or Redundant Information?-Insights from a Computational Study.

Pollnow S, Greiner J, Oesterlein T, Wulfers E, Loewe A, Dossel O Comput Math Methods Med. 2017; 2017:1686290.

PMID: 28553365 PMC: 5434470. DOI: 10.1155/2017/1686290.


References
1.
Haines D, WATSON D . Tissue heating during radiofrequency catheter ablation: a thermodynamic model and observations in isolated perfused and superfused canine right ventricular free wall. Pacing Clin Electrophysiol. 1989; 12(6):962-76. DOI: 10.1111/j.1540-8159.1989.tb05034.x. View

2.
Elvan A, Pride H, Eble J, Zipes D . Radiofrequency catheter ablation of the atria reduces inducibility and duration of atrial fibrillation in dogs. Circulation. 1995; 91(8):2235-44. DOI: 10.1161/01.cir.91.8.2235. View

3.
Haines D . The biophysics of radiofrequency catheter ablation in the heart: the importance of temperature monitoring. Pacing Clin Electrophysiol. 1993; 16(3 Pt 2):586-91. DOI: 10.1111/j.1540-8159.1993.tb01630.x. View

4.
Shahidi A, Savard P . A finite element model for radiofrequency ablation of the myocardium. IEEE Trans Biomed Eng. 1994; 41(10):963-8. DOI: 10.1109/10.324528. View

5.
Labonte S . A computer simulation of radio-frequency ablation of the endocardium. IEEE Trans Biomed Eng. 1994; 41(9):883-90. DOI: 10.1109/10.312096. View