» Articles » PMID: 11060951

Dental Post-operative Sensitivity Associated with a Gallium-based Restorative Material

Overview
Journal Br Dent J
Specialty Dentistry
Date 2000 Nov 4
PMID 11060951
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: This study forms part of a 2-year longitudinal clinical trial to compare the performance of a gallium-based restorative material (Galloy) with a high copper, mercury based (Dispersalloy) control material.

Method: Following Ethical Committee approval, 25 galloy restorations and 25 Dispersalloy controls were placed in 14 adult patients, by a single operator. The cavities were of moderate size, indicating the use of amalgam as the restorative material. All restorations were polished within 1 week of placement, photographed and a silicone impression of the tooth and restoration recorded. In addition, a visual analogue scale (VAS), indicating the extent of any post-operative sensitivity, was completed by each patient for each restoration, immediately prior to polishing. A score of 0 indicated no sensitivity, while a score of 10 indicated the greatest possible sensitivity. At 6-month recall, the VAS scores, silicone impressions and photographs were repeated.

Results: The mean sensitivity scores for the galloy and Dispersalloy restorations at 1 week were 5.1 (+/- 3.4) and 1.0 (+/- 1.5), respectively and at 6 months, 1.8 (+/- 3.0) and 0.2 (+/- 0.1) respectively. The differences between these means at 1 week and at 6 months were significant (P < 0.01).

Conclusion: Galloy restorations were associated with a much greater severity of post-operative sensitivity than Dispersalloy restorations.

Citing Articles

Alternating-Magnetic-Field-Mediated Wireless Manipulations of a Liquid Metal for Therapeutic Bioengineering.

Yu Y, Miyako E iScience. 2018; 3:134-148.

PMID: 30428316 PMC: 6137341. DOI: 10.1016/j.isci.2018.04.012.


Injectable 3-D fabrication of medical electronics at the target biological tissues.

Jin C, Zhang J, Li X, Yang X, Li J, Liu J Sci Rep. 2013; 3:3442.

PMID: 24309385 PMC: 3853658. DOI: 10.1038/srep03442.


Biomedical implementation of liquid metal ink as drawable ECG electrode and skin circuit.

Yu Y, Zhang J, Liu J PLoS One. 2013; 8(3):e58771.

PMID: 23472220 PMC: 3589353. DOI: 10.1371/journal.pone.0058771.