Slit Skiascopic-guided Ablation Using the Nidek Laser

Overview
Journal J Refract Surg
Date 2000 Oct 6
PMID 11019877
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To present the approach of using a scanning slit refractometer (the ARK 10000) in conjunction with a corneal topography system to guide customized corneal ablation. This diagnostic system is coupled with the Nidek EC-5000 system which combines scanning slit and a scanning small area ablation (1.0 mm) to perform a customized ablation.

Methods: The ARK 10000 diagnostic system which contains a scanning slit refractometer is described. Information generated from the ARK 10000 wavefront sensor and corneal topography system can be coupled to the new Nidek EC-5000 excimer laser system, which combines the larger area of scanning slit ablation with the small area (1.0 mm) ablation.

Results: The Nidek ARK 10000 diagnostic system captures wavefront information using a retinoscopic system which is converted into a refractive power map. This is different from other autorefraction systems in that it has four sensors at different diameters of the cornea and captures 1440 points in 0.4 seconds. This map is used in conjunction with corneal topography-captured simultaneously. This information is then combined to perform a customized ablation using the new Nidek EC-5000 system.

Conclusions: The ARK 10000 diagnostic system represents a different approach to customized ablation in that it combines a corneal topography system with a wavefront system and a larger treatment area of the traditional scanning slit ablation with a new small area ablation treatment for greater efficiency.

Citing Articles

The visual impact of higher-order aberrations in patients with pediatric blepharokeratoconjunctivitis.

Mendoza-Zamora C, Gonzalez-Godinez S, Ortiz-Morales G, Paez-Garza J, Rodriguez-Garcia A Int Ophthalmol. 2024; 44(1):60.

PMID: 38345707 DOI: 10.1007/s10792-024-03002-2.


Precision and agreement of higher order aberrations measured with ray tracing and Hartmann-Shack aberrometers.

Xu Z, Hua Y, Qiu W, Li G, Wu Q BMC Ophthalmol. 2018; 18(1):18.

PMID: 29374460 PMC: 5787271. DOI: 10.1186/s12886-018-0683-8.


Distribution of corneal and ocular spherical aberrations in eyes with cataract in the Taiwanese population.

Lai Y, Yeh S, Cheng H Taiwan J Ophthalmol. 2017; 5(2):72-75.

PMID: 29018671 PMC: 5602731. DOI: 10.1016/j.tjo.2015.03.003.


Investigation of the isoplanatic patch and wavefront aberration along the pupillary axis compared to the line of sight in the eye.

Nowakowski M, Sheehan M, Neal D, Goncharov A Biomed Opt Express. 2012; 3(2):240-58.

PMID: 22312578 PMC: 3269842. DOI: 10.1364/BOE.3.000240.


Correlation between contrast sensitivity and higher-order aberration based on pupil diameter after cataract surgery.

Yamaguchi T, Negishi K, Ohnuma K, Tsubota K Clin Ophthalmol. 2011; 5:1701-7.

PMID: 22205829 PMC: 3245194. DOI: 10.2147/OPTH.S21819.