Classification of Waist-acceleration Signals in a Continuous Walking Record

Overview
Journal Med Eng Phys
Date 2000 Oct 6
PMID 11018460
Citations 23
Authors
Affiliations
Soon will be listed here.
Abstract

We attempted to distinguish walking on level ground from walking on a stairway using waist acceleration signals. A triaxial accelerometer was fixed to the subject's waist and the three acceleration signals were recorded by a portable data logger at a sampling rate of 256 Hz. Twenty healthy male subjects were asked to walk through a corridor and up and down a stairway as a single sequence, without any instruction. The data were analyzed using discrete wavelet transform. Walking patterns were classified in two stages. In the first stage, the times when the walking pattern changed were detected using the low-frequency component of the anteroposterior acceleration (LF(A)) and of the vertical acceleration (LF(V)). In the second stage, the three types of walking patterns were classified by comparing powers of wavelet coefficients in the vertical direction (P(WCV)) and in the anteroposterior direction (RP(WCA)). Changes in walking patterns could be detected by using either LF(A) or LF(V). Walking down stairs could be distinguished from the other types of walking as it gave the largest value in P(WCV), and walking up stairs could be discriminated from level walking using RP(WCA). Level and stairway walking could be classified from continuous records of waist acceleration.

Citing Articles

Comparison of different prediction models for estimation of walking and running energy expenditure based on a wristwear three-axis accelerometer.

Xu L, Zhang J, Li Z, Liu Y, Jia Z, Han X Front Physiol. 2023; 14:1202737.

PMID: 38028785 PMC: 10643196. DOI: 10.3389/fphys.2023.1202737.


Human Activity Recognition of Individuals with Lower Limb Amputation in Free-Living Conditions: A Pilot Study.

Jamieson A, Murray L, Stankovic L, Stankovic V, Buis A Sensors (Basel). 2021; 21(24).

PMID: 34960463 PMC: 8704297. DOI: 10.3390/s21248377.


Wearable Device for Yogic Breathing with Real-Time Heart Rate and Posture Monitoring.

Puranik A, Kanthi M, Nayak A J Med Signals Sens. 2021; 11(4):253-261.

PMID: 34820297 PMC: 8588879. DOI: 10.4103/jmss.JMSS_54_20.


Towards Motor-Based Early Detection of Autism Red Flags: Enabling Technology and Exploratory Study Protocol.

Bondioli M, Chessa S, Narzisi A, Pelagatti S, Zoncheddu M Sensors (Basel). 2021; 21(6).

PMID: 33799643 PMC: 7998381. DOI: 10.3390/s21061971.


Subtask Segmentation of Timed Up and Go Test for Mobility Assessment of Perioperative Total Knee Arthroplasty.

Hsieh C, Huang H, Liu K, Chen K, Hsu S, Chan C Sensors (Basel). 2020; 20(21).

PMID: 33167444 PMC: 7663910. DOI: 10.3390/s20216302.