» Articles » PMID: 10794783

Superior Vena Cava Flow in Newborn Infants: a Novel Marker of Systemic Blood Flow

Overview
Date 2000 May 5
PMID 10794783
Citations 88
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Ventricular outputs cannot be used to assess systemic blood flow in preterm infants because they are confounded by shunts through the ductus arteriosus and atrial septum. However, flow measurements in the superior vena cava (SVC) can assess blood returning from the upper body and brain.

Objectives: To describe a Doppler echocardiographic technique that measures blood flow in the SVC, to test its reproducibility, and to establish normal ranges.

Design: SVC flow was assessed together with right ventricular output and atrial or ductal shunting. Normal range was established in 14 infants born after 36 weeks' gestation (2 measurements taken in the first 48 hours) and 25 uncomplicated infants born before 30 weeks (4 measurements taken in the first 48 hours). Intra-observer and interobserver variability were tested in 20 preterm infants.

Results: In 14 infants born after 36 weeks, median SVC flow rose from 76 ml/kg/min on day 1 to 93 ml/kg/min on day 2; in 25 uncomplicated very preterm infants, it rose from 62 ml/kg/min at 5 hours to 86 ml/kg/min at 48 hours. The lowest SVC flow for the preterm babies rose from 30 ml/kg/min at 5 hours to 46 ml/kg/min by 48 hours. Median intra-observer and interobserver variability were 8. 1% and 14%, respectively. In preterm babies with a closed duct, SVC flow was a mean of 37% of left ventricular output and the two measures correlated significantly.

Conclusions: This technique can assess blood flow from the upper body, including the brain, in the crucial early postnatal period, and might allow more accurate assessment of the status of systemic blood flow and response to treatment.

Citing Articles

The effect of NHFOV on hemodynamics in mild and moderately preterm neonates: a randomized clinical trial.

Farag M, Hassan M, Fasseeh N, Ghazal H Eur J Pediatr. 2024; 183(8):3263-3275.

PMID: 38703279 PMC: 11263252. DOI: 10.1007/s00431-024-05515-5.


Biventricular function in preterm infants with patent ductus arteriosus ligation: A three-dimensional echocardiographic study.

Toyoshima K, Aoki H, Noguchi T, Saito N, Shimizu T, Kemmotsu T Pediatr Res. 2024; 96(3):773-784.

PMID: 38615076 PMC: 11499271. DOI: 10.1038/s41390-024-03180-w.


Association between patent ductus arteriosus flow and home oxygen therapy in extremely preterm infants.

Termerova J, Kubena A, Liska K, Tomek V, Plavka R Pediatr Res. 2024; 96(1):208-215.

PMID: 38454005 PMC: 11257949. DOI: 10.1038/s41390-024-03120-8.


Relationship between cerebral oxygenation, cardiac output, and blood pressure during transitional period in extremely low gestational age neonates.

Deshpande P, Barbosa de Olivera C, Jain A, Hahn C, Shah P, Guerguerian A Front Pediatr. 2023; 11:1187769.

PMID: 37654688 PMC: 10466030. DOI: 10.3389/fped.2023.1187769.


Effects of umbilical cord milking versus delayed cord clamping on systemic blood flow in intrauterine growth-restricted neonates: A randomized controlled trial.

Angadi C, Singh P, Shrivastava Y, Priyadarshi M, Chaurasia S, Chaturvedi J Eur J Pediatr. 2023; 182(9):4185-4194.

PMID: 37439849 DOI: 10.1007/s00431-023-05105-x.


References
1.
Kluckow M, Evans N . Low superior vena cava flow and intraventricular haemorrhage in preterm infants. Arch Dis Child Fetal Neonatal Ed. 2000; 82(3):F188-94. PMC: 1721081. DOI: 10.1136/fn.82.3.f188. View

2.
Oppo K, Leen E, Angerson W, Cooke T, McArdle C . Doppler perfusion index: an interobserver and intraobserver reproducibility study. Radiology. 1998; 208(2):453-7. DOI: 10.1148/radiology.208.2.9680575. View

3.
FROYSAKER T, CAPPELEN Jr C . Flow pattern in central and peripheral human veins. A pilot study. Scand J Thorac Cardiovasc Surg. 1970; 4(3):262-6. DOI: 10.3109/14017437009131941. View

4.
FROYSAKER T . Normal flow pattern in the superior vena cava in man during thoracotomy. Scand J Thorac Cardiovasc Surg. 1972; 6(1):22-32. DOI: 10.3109/14017437209134286. View

5.
FROYSAKER T . Abnormal flow pattern in the superior vena cava induced by arrhythmias. A peroperative flowmetric study in man. Scand J Thorac Cardiovasc Surg. 1972; 6(2):140-8. DOI: 10.3109/14017437209134792. View