» Articles » PMID: 10728307

Blood Flow Distributions by Microsphere Deposition Methods

Overview
Journal Cardiovasc Res
Date 2000 Mar 23
PMID 10728307
Citations 56
Authors
Affiliations
Soon will be listed here.
Abstract

The art and science of the use of deposition markers for the estimation of blood flow distributions throughout the body and within organs is reviewed. Development of diffusible tracer techniques started 50 years ago. Twenty years later, radioactive 15 micron microspheres became the standard marker. Early studies on small animals, fetal sheep in 1967 and rats in 1976, provoked much of the technical development. Needs for avoiding the use of radioactivity, for having long lasting labels, and for providing higher spatial resolution, are driving the continuing exploration of newer techniques using colored and fluorescent microspheres and molecular deposition markers. Strengths and weaknesses of the various methods are compared.

Citing Articles

Systematic evaluation of MRI-based characterization of tumor-associated vascular morphology and hemodynamics via a dynamic digital phantom.

Wu C, Hormuth 2nd D, Easley T, Pineda F, Karczmar G, Yankeelov T J Med Imaging (Bellingham). 2024; 11(2):024002.

PMID: 38463607 PMC: 10921778. DOI: 10.1117/1.JMI.11.2.024002.


Crafting a Rigorous, Clinically Relevant Large Animal Model of Chronic Myocardial Ischemia: What Have We Learned in 20 Years?.

Stone C, Harris D, Broadwin M, Kanuparthy M, Sabe S, Xu C Methods Protoc. 2024; 7(1).

PMID: 38392691 PMC: 10891802. DOI: 10.3390/mps7010017.


Correlation of Perfusion Metrics with Ki-67 Proliferation Index and Axillary Involvement as a Prognostic Marker in Breast Carcinoma Cases: A Dynamic Contrast-Enhanced Perfusion MRI Study.

Uncu U, Aydin Aksu S Diagnostics (Basel). 2023; 13(20).

PMID: 37892081 PMC: 10606869. DOI: 10.3390/diagnostics13203260.


In Vitro Validation of a New Tissue Oximeter Using Visible Light.

Nasseri N, Kleiser S, Wolf U, Wolf M Adv Exp Med Biol. 2022; 1395:217-221.

PMID: 36527640 DOI: 10.1007/978-3-031-14190-4_36.


Investigating changes in blood-cerebrospinal fluid barrier function in a rat model of chronic hypertension using non-invasive magnetic resonance imaging.

Perera C, Tolomeo D, Baker R, Ohene Y, Korsak A, Lythgoe M Front Mol Neurosci. 2022; 15:964632.

PMID: 36117909 PMC: 9478509. DOI: 10.3389/fnmol.2022.964632.


References
1.
Nose Y, Nakamura T, Nakamura M . The microsphere method facilitates statistical assessment of regional blood flow. Basic Res Cardiol. 1985; 80(4):417-29. DOI: 10.1007/BF01908186. View

2.
Raab S, Thein E, Harris A, Messmer K . A new sample-processing unit for the fluorescent microsphere method. Am J Physiol. 1999; 276(5):H1801-6. DOI: 10.1152/ajpheart.1999.276.5.H1801. View

3.
REED Jr J, Wood E . Effect of body position on vertical distribution of pulmonary blood flow. J Appl Physiol. 1970; 28(3):303-11. DOI: 10.1152/jappl.1970.28.3.303. View

4.
Hales J, CLIFF W . Direct observations of the behaviour of microspheres in microvasculature. Bibl Anat. 1977; (15 Pt 1):87-91. View

5.
Hodeige D, De Pauw M, EECHAUTE W, Weyne J, Heyndrickx G . On the validity of blood flow measurement using colored microspheres. Am J Physiol. 1999; 276(4):H1150-8. DOI: 10.1152/ajpheart.1999.276.4.H1150. View