» Articles » PMID: 10330266

A New Sample-processing Unit for the Fluorescent Microsphere Method

Overview
Journal Am J Physiol
Specialty Physiology
Date 1999 May 18
PMID 10330266
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

The use of fluorescent-labeled microspheres (FM) for measurement of regional blood flow is an attractive alternative to the use of radioactive-labeled microspheres. In the FM method the FM have to be completely recovered from the tissue samples in a time- and labor-intensive process. For this reason, a considerable loss of FM is possible. The aim of this study was to develop a filtration device that allows the tissue sample to remain in a single container throughout the procedure to make the process easier and to avoid the loss of FM. The core of the sample-processing unit (SPU) is a single-tube filtration device with a polyamide wire mesh. The protocol for processing tissue from different organs (heart, kidney, liver, spleen, intestine, muscle, bone, lung, brain) was modified and thus shortened significantly. Furthermore, the SPU allows direct filtration of the blood reference sample without previous digestion. Different experiments showed that the SPU in combination with the new protocol excludes the loss of 15-micrometers FM. The modifications of the whole procedure render it faster and highly standardized.

Citing Articles

Cooling to Hypothermic Circulatory Arrest by Immersion vs. Cardiopulmonary Bypass (CPB): Worse Outcome After Rewarming in Immersion Cooled Pigs.

Filseth O, Hermansen S, Kondratiev T, Sieck G, Tveita T Front Physiol. 2022; 13:862729.

PMID: 35431978 PMC: 9008231. DOI: 10.3389/fphys.2022.862729.


Notch-independent RBPJ controls angiogenesis in the adult heart.

Diaz-Trelles R, Scimia M, Bushway P, Tran D, Monosov A, Monosov E Nat Commun. 2016; 7:12088.

PMID: 27357444 PMC: 4931341. DOI: 10.1038/ncomms12088.


Small-volume resuscitation from hemorrhagic shock with polymerized human serum albumin.

Messmer C, Yalcin O, Palmer A, Cabrales P Am J Emerg Med. 2011; 30(8):1336-46.

PMID: 22100469 PMC: 3289752. DOI: 10.1016/j.ajem.2011.09.018.


Renal hypoperfusion and impaired endothelium-dependent vasodilation in an animal model of VILI: the role of the peroxynitrite-PARP pathway.

Vaschetto R, Kuiper J, Musters R, Eringa E, Della Corte F, Murthy K Crit Care. 2010; 14(2):R45.

PMID: 20346119 PMC: 2887157. DOI: 10.1186/cc8932.


Measuring bone blood supply in mice using fluorescent microspheres.

Serrat M Nat Protoc. 2009; 4(12):1779-58.

PMID: 19893510 DOI: 10.1038/nprot.2009.190.