» Articles » PMID: 10714833

Estimation of Cardiac Preload Changes by Systolic Pressure Variation in Pigs Undergoing Pneumoperitoneum

Overview
Specialty Anesthesiology
Date 2000 Mar 14
PMID 10714833
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Variations in systolic pressure arterial waveform (SPV) and its component have been shown to be a reasonable indicator of left ventricular preload. Creation of a pneumoperitoneum (PMOP) by insufflation of CO2 increases intrathoracic pressure, leading to overestimation of preload as assessed by pressure methods. The purpose of this study was to compare SPV with other standard methods in anaesthetized pigs.

Methods: We measured SPV and its DeltaDown component (deltaDown), pulmonary artery occlusion pressure (PAOP) and left ventricular short-axis cross-sectional area using transthoracic echocardiography (TTE) in 7 pigs, at baseline, after 12 mmHg PMOP and after an intravascular load with 10 ml/kg hydroxylethylstarch (HES).

Results: PMOP increased SPV from 12.9+/-4.9 to 16.9+/-5.5 mmHg (P<0.05) and decreased pulmonary compliance, with no change in PAOP or end-diastolic area assesssed by TTE. Intravascular volume loading significantly decreased SPV from 16.9+/-5.5 to 11.2+/-4.9 mmHg and deltaDown from 9.9+/-7.1 to 5.2+/-4.5 (P<0.05), and increased PAOP and end-diastolic area. Significant correlation between changes in deltaDown and EDA was noted following HES (r=0.78, P<0.05).

Conclusion: In anaesthetized pigs, the creation of a PMOP alters SPV, likely by decreasing lung compliance. Once PMOP is established, changes in cardiac preload could be estimated by SPV analysis.

Citing Articles

A Mini-Fluid Challenge to Predict Fluid Responsiveness in Swine.

Yoshida K J Am Assoc Lab Anim Sci. 2025; 64(1):106-110.

PMID: 40035283 PMC: 11808368. DOI: 10.30802/AALAS-JAALAS-24-000026.


Comparison of ability of pulse pressure variation to predict fluid responsiveness in prone and supine position: an observational study.

Ali A, Abdullah T, Sabanci P, Dogan L, Orhan-Sungur M, Akinci I J Clin Monit Comput. 2018; 33(4):573-580.

PMID: 30117033 DOI: 10.1007/s10877-018-0195-3.


Influence of tidal volume on pulse pressure variation and stroke volume variation during experimental intra-abdominal hypertension.

Diaz F, Erranz B, Donoso A, Salomon T, Cruces P BMC Anesthesiol. 2015; 15:127.

PMID: 26395001 PMC: 4579832. DOI: 10.1186/s12871-015-0105-x.


Stroke volume variation to guide fluid therapy: is it suitable for high-risk surgical patients? A terminated randomized controlled trial.

Jammer I, Tuovila M, Ulvik A Perioper Med (Lond). 2015; 4:6.

PMID: 26203353 PMC: 4511544. DOI: 10.1186/s13741-015-0016-x.


Pneumoperitoneum affects stroke volume variation in humans.

Wajima Z, Shiga T, Imanaga K J Anesth. 2014; 29(4):508-14.

PMID: 25547610 DOI: 10.1007/s00540-014-1963-y.