Cognitive, Cardiac, and Physiological Safety Studies in Ultra High Field Magnetic Resonance Imaging

Overview
Publisher Elsevier
Specialty Radiology
Date 1999 Dec 28
PMID 10609989
Citations 41
Authors
Affiliations
Soon will be listed here.
Abstract

A systematic analysis of the effect of an 8.0 tesla static magnetic field on physiological and/or cognitive function is presented in the normal volunteer and in the swine. A study of ten human subjects revealed no evidence of detectable changes in body temperature, heart rate, respiratory rate, systolic pressure, and diastolic blood pressure after 1 hour of exposure. In addition, no cognitive changes were detected. Important ECG changes were noted which were related both to the position of the subject in the magnet and to the absolute strength of the magnetic field. As such, the ECG tracing at 8 tesla was not diagnostically useful. Nonetheless, all subjects exhibited normal ECG readings both before and following exposure to the 8 tesla field. Cardiac function was also examined in detail in the swine. No significant changes in body temperature, heart rate, left ventricular pressure, left ventricular end diastollic pressure, time rate of change of left ventricular pressure, myocardial stiffness index, cardiac output, systolic volume, troponin, and potassium levels could be detected following 3 h of exposure to a field strength of 8.0 tesla. It is concluded that no short term cardiac or cognitive effects are observed following significant exposure to a magnetic field of up to 8.0 tesla.

Citing Articles

Induced electric fields in MRI settings and electric vestibular stimulations: same vestibular effects?.

Bouisset N, Laakso I Exp Brain Res. 2024; 242(11):2493-2507.

PMID: 39261353 DOI: 10.1007/s00221-024-06910-y.


Super-resolution reconstruction in ultrahigh-field MRI.

Payne M, Mali I, Mueller T, Cain M, Segev R, Bossmann S Biophys Rep (N Y). 2023; 3(2):100107.

PMID: 37114210 PMC: 10126864. DOI: 10.1016/j.bpr.2023.100107.


Bi-ventricular assessment with cardiovascular magnetic resonance at 5 Tesla: A pilot study.

Lin L, Liu P, Sun G, Wang J, Liang D, Zheng H Front Cardiovasc Med. 2022; 9:913707.

PMID: 36172590 PMC: 9510665. DOI: 10.3389/fcvm.2022.913707.


Repetitive T1 Imaging Influences Gray Matter Volume Estimations in Structural Brain Imaging.

Broessner G, Ellerbrock I, Menz M, Frank F, Verius M, Gaser C Front Neurol. 2021; 12:755749.

PMID: 34777226 PMC: 8581175. DOI: 10.3389/fneur.2021.755749.


Long-term behavioral effects observed in mice chronically exposed to static ultra-high magnetic fields.

Tkac I, Benneyworth M, Nichols-Meade T, Steuer E, Larson S, Metzger G Magn Reson Med. 2021; 86(3):1544-1559.

PMID: 33821502 PMC: 8569931. DOI: 10.1002/mrm.28799.