Background: Observer variability has been shown with interpretation of planar thallium-201 images. The interpretive reproducibility of technetium-99m sestamibi tomographic imaging is unknown. This study evaluated the interpretive reproducibility of interpretable Tc-99m sestamibi tomographic images among nuclear cardiologists with a wide range of training and experience.

Methods: Three experienced readers (EX) and 3 less-experienced readers (LEX) interpreted 138 exercise and rest Tc-99m sestamibi tomographic images (101 were abnormal in patients with coronary artery disease [CAD], 37 were normal in patients with <5% likelihood of CAD) twice in random sequence without clinical data. Images of good to excellent quality were randomly selected from a database at 2 nuclear cardiology laboratories. Intraobserver and interobserver agreement for global, left anterior descending (LAD) territory, non-LAD first (normal/abnormal) and second (normal/fixed/reversible) order, and defect extent (normal/single-vessel CAD/multi-vessel CAD) were assessed with percent agreement and Cohen's kappa (kappa) statistic.

Results: With regard to intraobserver agreement, first and second order ranged from 87% to 94% and 80% to 90% for global, 82% to 96% and 78% to 95% for LAD, and 88% to 91% and 80% to 90% for non-LAD, respectively. Defect extent ranged from 75% to 90%. There were no differences between EX and LEX for global and non-LAD first and second order, LAD first order, and defect extent. LAD second order was 93% for EX compared with 88% (P = .015) for LEX. With regard to interobserver agreement, first and second order ranged from 73% to 89% and 64% to 85% for global, 73% to 93% and 69% to 91% for LAD, and 76% to 88% and 68% to 84% for non-LAD, respectively. Defect extent ranged from 61% to 82%. Global first and second order ranged from 85% to 87% and 78% to 82% for EX compared with 73% to 84% and 64% to 79% for LEX. LAD first and second order ranged from 89% to 91% and 88% to 89% for EX compared with 73% to 91% and 69% to 70% for LEX. Non-LAD first and second order ranged from 82% to 86% and 76% to 77% for EX compared with 76% to 86% and 68% to 81% for LEX. Defect extent ranged from 69% to 75% for EX compared with 59% to 77% for LEX.

Conclusions: There is moderate to excellent interpretive reproducibility with stress Tc-99m sestamibi SPECT imaging among nuclear cardiologists with a wide range of training and experience.

Citing Articles

Development, diagnostic performance, and interobserver agreement of a F-flurpiridaz PET automated perfusion quantitation system.

Packard R, Cooke C, Van Train K, Votaw J, Sayre J, Lazewatsky J J Nucl Cardiol. 2020; 29(2):698-708.

PMID: 32895856 PMC: 7936994. DOI: 10.1007/s12350-020-02335-6.


Prediction of revascularization after myocardial perfusion SPECT by machine learning in a large population.

Arsanjani R, Dey D, Khachatryan T, Shalev A, Hayes S, Fish M J Nucl Cardiol. 2014; 22(5):877-84.

PMID: 25480110 PMC: 4859156. DOI: 10.1007/s12350-014-0027-x.


Two-position supine/prone myocardial perfusion SPECT (MPS) imaging improves visual inter-observer correlation and agreement.

Arsanjani R, Hayes S, Fish M, Shalev A, Nakanishi R, Thomson L J Nucl Cardiol. 2014; 21(4):703-11.

PMID: 24807622 PMC: 4158826. DOI: 10.1007/s12350-014-9895-3.


Improved accuracy of myocardial perfusion SPECT for detection of coronary artery disease by machine learning in a large population.

Arsanjani R, Xu Y, Dey D, Vahistha V, Shalev A, Nakanishi R J Nucl Cardiol. 2013; 20(4):553-62.

PMID: 23703378 PMC: 3732038. DOI: 10.1007/s12350-013-9706-2.


Improved accuracy of myocardial perfusion SPECT for the detection of coronary artery disease using a support vector machine algorithm.

Arsanjani R, Xu Y, Dey D, Fish M, Dorbala S, Hayes S J Nucl Med. 2013; 54(4):549-55.

PMID: 23482666 PMC: 3615055. DOI: 10.2967/jnumed.112.111542.


References
1.
Hendel R, Verani M, Miller D, Wackers F, McMahon M, Cerqueira M . Diagnostic utility of tomographic myocardial perfusion imaging with technetium 99m furifosmin (Q12) compared with thallium 201: results of a phase III multicenter trial. J Nucl Cardiol. 1996; 3(4):291-300. DOI: 10.1016/s1071-3581(96)90088-4. View

2.
Hendel R, Parker M, Wackers F, Rigo P, Lahiri A, Zaret B . Reduced variability of interpretation and improved image quality with a technetium 99m myocardial perfusion agent: comparison of thallium 201 and technetium 99m-labeled tetrofosmin. J Nucl Cardiol. 1994; 1(6):509-14. DOI: 10.1007/BF02939973. View

3.
Picano E, Lattanzi F, Orlandini A, Marini C, LAbbate A . Stress echocardiography and the human factor: the importance of being expert. J Am Coll Cardiol. 1991; 17(3):666-9. DOI: 10.1016/s0735-1097(10)80182-2. View

4.
Taillefer R, Lambert R, Dupras G, Gregoire J, Leveille J, Essiambre R . Clinical comparison between thallium-201 and Tc-99m-methoxy isobutyl isonitrile (hexamibi) myocardial perfusion imaging for detection of coronary artery disease. Eur J Nucl Med. 1989; 15(6):280-6. DOI: 10.1007/BF00435466. View

5.
Golub R, McClellan J, Herman S, Travin M, Kline G, Aitken P . Effectiveness of nuclear cardiology training guidelines: a comparison of trainees with experienced readers. J Nucl Cardiol. 1996; 3(2):114-8. DOI: 10.1016/s1071-3581(96)90003-3. View