Tomotherapy
Overview
Authors
Affiliations
Tomotherapy is delivery of intensity-modulated, rotational radiation therapy using a fan-beam delivery. The NOMOS (Sewickley, PA) Peacock system is an example of sequential (or serial) tomotherapy that uses a fast-moving, actuator-driven multileaf collimator attached to a conventional C-arm gantry to modulate the beam intensity. In helical tomotherapy, the patient is continuously translated through a ring gantry as the fan beam rotates. The beam delivery geometry is similar to that of helical computed tomography (CT) and requires the use of slip rings to transmit power and data. A ring gantry provides a stable and accurate platform to perform tomographic verification using an unmodulated megavoltage beam. Moreover, megavoltage tomograms have adequate tissue contrast and resolution to provide setup verification. Assuming only translational and rotational offset errors, it is also possible to determine the offsets directly from tomographic projections, avoiding the time-consuming image reconstruction operation. The offsets can be used to modify the leaf delivery pattern to match the beam to the patient's anatomy on each day of a course of treatment. If tomographic representations of the patient are generated, this information can also be used to perform dose reconstruction. In this way, the actual dose distribution delivered can be superimposed onto the tomographic representation of the patient obtained at the time of treatment. The results can be compared with the planned isodose on the planning CT. This comparison may be used as an accurate basis for adaptive radiotherapy whereby the optimized delivery is modified before subsequent fractions. The verification afforded tomotherapy allows more precise conformal therapy. It also enables conformal avoidance radiotherapy, the complement to conformal therapy, for cases in which the tumor volume is ill-defined, but the locations of sensitive structures are adequately determined. A clinical tomotherapy unit is under construction at the University of Wisconsin.
Utility of photon-counting detectors for MV-kV dual-energy computed tomography imaging.
Jadick G, Ventura M, La Riviere P J Med Imaging (Bellingham). 2024; 11(Suppl 1):S12811.
PMID: 39735347 PMC: 11670364. DOI: 10.1117/1.JMI.11.S1.S12811.
Monte Carlo Simulation for the Radixact™ Tomotherapy Linac Using EGSnrc.
Makrani D, Nedaei H, Geraily G, Khorami-Moghaddam A, Banaee N, Jassim H J Med Phys. 2024; 49(3):379-386.
PMID: 39526159 PMC: 11548081. DOI: 10.4103/jmp.jmp_29_24.
An overview of artificial intelligence in medical physics and radiation oncology.
Liu J, Xiao H, Fan J, Hu W, Yang Y, Dong P J Natl Cancer Cent. 2024; 3(3):211-221.
PMID: 39035195 PMC: 11256546. DOI: 10.1016/j.jncc.2023.08.002.
Dual-energy computed tomography imaging with megavoltage and kilovoltage X-ray spectra.
Jadick G, Schlafly G, La Riviere P J Med Imaging (Bellingham). 2024; 11(2):023501.
PMID: 38445223 PMC: 10910563. DOI: 10.1117/1.JMI.11.2.023501.
Najem E, Marin T, Zhuo Y, Lahoud R, Tian F, Beddok A Radiother Oncol. 2024; 194:110186.
PMID: 38412906 PMC: 11042980. DOI: 10.1016/j.radonc.2024.110186.