[Evaluation of Loosening of Different Total Hip Models and Neck Lengths (author's Transl)]
Overview
Orthopedics
Affiliations
The percentage of aseptic loosening of different types of total hip prostheses in 771 cases has been evaluated. The time of follow-up ranged between 1/2 and 6 years. In prostheses of the Charnley-Müller type of loosening was 7.8% in the Charnley-Müller-Weller type with a 2-year shorter follow-up it was 2.4%. No loosening was found during the last 2 1/2 years when the prosthesis of Beck was used, which has an increased femoral shaft-neck angle and a longer stem. When a longer neck was used, the loosening averaged 5.6%. In cases of normal neck-length it was 3.6%. From the biomechanical standpoint it seems preferable to use prostheses with an increased shaft-neck angle. Comparing the rates of loosening as reported in the literature it appears that prostheses where the femur is displaced medially (by a small femoral head or increased shaft-neck angle) show a very low rate of loosening. Models with metal sockets (McKee-Farrar and Weber-Huggler) seem to have a higher rate of loosening than models with polyethylene sockets.
Technological test-methods for hip prostheses.
Ungethum M Arch Orthop Trauma Surg (1978). 1980; 97(4):285-92.
PMID: 7458613 DOI: 10.1007/BF00380710.
An analysis of 119 loosenings in total hip endoprostheses.
Bosch P, KRISTEN H, Zweymuller K Arch Orthop Trauma Surg (1978). 1980; 96(2):83-90.
PMID: 7377936 DOI: 10.1007/BF00433286.
Results of alloarthroplasty of the hip joint.
Oberthaler W, Bauer R, Sattler K Arch Orthop Trauma Surg (1978). 1980; 96(4):247-58.
PMID: 6994678 DOI: 10.1007/BF00432862.
Morscher E, Schmassmann A Arch Orthop Trauma Surg (1978). 1983; 101(2):137-43.
PMID: 6847350 DOI: 10.1007/BF00433274.