1.
Urago Y, Sakama M, Sakata D, Fukuda S, Katayose T, Chang W
Phys Med Biol
. 2023 Aug;
68(18).
PMID: 37579752
. In current dosimetry protocols, the estimated uncertainty of the measured absorbed dose to waterin carbon-ion beams is approximately 3%. This large uncertainty is mainly contributed by the standard uncertainty...
2.
Miyasaka R, Cho S, Hiraoka T, Chiba K, Kawachi T, Katayose T, et al.
J Appl Clin Med Phys
. 2022 Jan;
23(3):e13519.
PMID: 35001518
Purpose: The dual-layer multi-leaf collimator (MLC) in Halcyon involves further complexities in the dose calculation process, because the leaf-tip transmission varies according to the leaf trailing pattern. For the volumetric...
3.
Kodama T, Yasui K, Nishioka S, Miyaura K, Takakura T, Katayose T, et al.
J Radiat Res
. 2021 May;
62(4):726-734.
PMID: 34036361
To understand the current state of flattening filter-free (FFF) beam implementation in C-arm linear accelerators (LINAC) in Japan, the quality assurance (QA)/quality control (QC) 2018-2019 Committee of the Japan Society...
4.
Yamauchi R, Igari M, Kasai Y, Hariu M, Suda Y, Kawachi T, et al.
Med Phys
. 2020 Aug;
47(10):5324-5332.
PMID: 32786073
Purpose: Ionization chambers are widely used for dosimetry with megavoltage photon beams. Several properties of ionization chambers, including the cable effect, polarity effect, and ion recombination loss, are described in...
5.
Kawachi T, Saitoh H, Katayose T, Tohyama N, Miyasaka R, Cho S, et al.
Med Phys
. 2019 Aug;
46(11):5185-5194.
PMID: 31386762
Purpose: The ICRU has published new recommendations for ionizing radiation dosimetry. In this work, the effect of recommendations on the water-to-air and graphite-to-air restricted mass electronic stopping power ratios (s...
6.
Miyasaka R, Saitoh H, Kawachi T, Katayose T, Cho S, Yamauchi R, et al.
J Appl Clin Med Phys
. 2019 Jul;
20(8):98-104.
PMID: 31355984
Respiratory-gated volumetric modulated arc therapy (gated VMAT) involves further complexities to the dose delivery process because the gantry rotation must repeatedly stop and restart according to the gating signals. In...
7.
Hashimoto S, Fujita Y, Katayose T, Mizuno H, Saitoh H, Karasawa K
Med Phys
. 2017 Nov;
45(1):382-390.
PMID: 29131409
Purpose: We evaluated the energy responses of a radiophotoluminescent glass dosimeter (RPLD) to variations in small-field and intensity-modulated radiation therapy (IMRT) conditions using experimental measurements and Monte Carlo simulation. Methods:...
8.
Chang W, Koba Y, Katayose T, Yasui K, Omachi C, Hariu M, et al.
Phys Med Biol
. 2017 Oct;
62(23):8869-8881.
PMID: 28980978
To measure the absorbed dose to water D in proton beams using a radiophotoluminescent glass dosimeter (RGD), a method with the correction for the change of the mass stopping power...
9.
Kawachi T, Katayose T, Kodama T, Miyasaka R, Shimizu M, Saitoh H
Igaku Butsuri
. 2017 Sep;
37(1):25-33.
PMID: 28924095
In Japan and North America, different dosimetry protocols have been implemented to determine the absorbed dose to water: JSMP Standard Dosimetry 12 and AAPM TG-51 addendum. In this study, Japanese...
10.
McEwen M, DeWerd L, Ibbott G, Followill D, Rogers D, Seltzer S, et al.
Igaku Butsuri
. 2017 Sep;
37(1):2-24.
PMID: 28924094
No abstract available.