» Authors » Subramanian V Sundramoorthy

Subramanian V Sundramoorthy

Explore the profile of Subramanian V Sundramoorthy including associated specialties, affiliations and a list of published articles. Areas
Snapshot
Articles 13
Citations 199
Followers 0
Related Specialties
Top 10 Co-Authors
Published In
Affiliations
Soon will be listed here.
Recent Articles
1.
Gertsenshteyn I, Epel B, Giurcanu M, Barth E, Lukens J, Hall K, et al.
Front Med (Lausanne) . 2023 Dec; 10:1339872. PMID: 38116039
[This corrects the article DOI: 10.3389/fmed.2023.1269689.].
2.
Gertsenshteyn I, Epel B, Giurcanu M, Barth E, Lukens J, Hall K, et al.
Front Med (Lausanne) . 2023 Oct; 10:1269689. PMID: 37904839
Background: Clinical attempts to find benefit from specifically targeting and boosting resistant hypoxic tumor subvolumes have been promising but inconclusive. While a first preclinical murine tumor type showed significant improved...
3.
Epel B, Viswakarma N, Sundramoorthy S, Pawar N, Kotecha M
Mol Imaging Biol . 2023 Sep; 26(3):403-410. PMID: 37715089
Purpose: Spatial heterogeneity in tumor hypoxia is one of the most important factors regulating tumor growth, development, aggressiveness, metastasis, and affecting treatment outcome. Most solid tumors are known to have...
4.
Epel B, Maggio M, Barth E, Miller R, Pelizzari C, Krzykawska-Serda M, et al.
Int J Radiat Oncol Biol Phys . 2018 Nov; 103(4):977-984. PMID: 30414912
Purpose: It has been known for over 100 years that tumor hypoxia, a near-universal characteristic of solid tumors, decreases the curative effectiveness of radiation therapy. However, to date, there are...
5.
Boris E, Sundramoorthy S, Halpern H
Concepts Magn Reson Part B Magn Reson Eng . 2018 Mar; 47B(2). PMID: 29576754
A simple scheme for dynamically switching the quality factor, Q, of a Loop-Gap Resonator (LGR); working at 250 MHz is presented. The addition of this Q-modulator resulted in 30% improvement...
6.
Rinard G, Quine R, Buchanan L, Eaton S, Eaton G, Epel B, et al.
Appl Magn Reson . 2018 Feb; 48(11-12):1227-1247. PMID: 29391664
Resonators for preclinical electron paramagnetic resonance imaging have been designed primarily for rodents and rabbits and have internal diameters between 16 and 51 mm. Lumped circuit resonators include loop-gap, Alderman-Grant,...
7.
Sundramoorthy S, Epel B, Halpern H
Appl Magn Reson . 2017 Nov; 48(8):805-811. PMID: 29151678
A magnetometer designed for permanent magnet manufacturing and operated around 25 mT with 10ppm absolute accuracy is described. The magnetometer uses pulse electron paramagnetic resonance (EPR) methodology. The use of...
8.
Epel B, Sundramoorthy S, Krzykawska-Serda M, Maggio M, Tseytlin M, Eaton G, et al.
J Magn Reson . 2017 Jan; 276:31-36. PMID: 28092786
Thiol redox status is an important physiologic parameter that affects the success or failure of cancer treatment. Rapid scan electron paramagnetic resonance (RS EPR) is a novel technique that has...
9.
Sundramoorthy S, Epel B, Halpern H
J Magn Reson . 2014 Feb; 240:45-51. PMID: 24530507
A 250 MHz bimodal resonator with a 19 mm internal diameter for in vivo pulse electron paramagnetic resonance (EPR) imaging is presented. Two separate coaxial cylindrical resonators inserted one into...
10.
Epel B, Sundramoorthy S, Mailer C, Halpern H
Concepts Magn Reson Part B Magn Reson Eng . 2011 Sep; 33B(3):163-176. PMID: 19924261
A versatile 250 MHz pulse electron paramagnetic resonance (EPR) instrument for imaging of small animals is presented. Flexible design of the imager hardware and software makes it possible to use...