» Authors » Richard D Peindl

Richard D Peindl

Explore the profile of Richard D Peindl including associated specialties, affiliations and a list of published articles. Areas
Snapshot
Articles 31
Citations 349
Followers 0
Related Specialties
Top 10 Co-Authors
Published In
Affiliations
Soon will be listed here.
Recent Articles
1.
Trofa D, Ruder J, Yeatts N, Peindl R, Habet N, Saltzman B, et al.
Arthroscopy . 2020 Jun; 36(11):2805-2811. PMID: 32554073
Purpose: The purpose of this study was to evaluate the cyclic displacement, stiffness, and ultimate load to failure of 3 all-suture anchors in human cadaveric greater tuberosities. Methods: Three all-suture...
2.
Newman M, Hirsch M, Peindl R, Habet N, Tsai T, Runyon M, et al.
Gait Posture . 2019 Dec; 76:193-197. PMID: 31862669
Background: Wearable sensors have allowed researchers to instrument tests of gait-related mobility, including the widely used timed 'up-and-go' test (TUG). Currently, there is a lack of instrumented test data on...
3.
Vajapey S, Bong M, Peindl R, Bosse M, Ly T
J Orthop Trauma . 2019 Oct; 34(1):e20-e25. PMID: 31567796
Objectives: To describe surgical technique for proper placement of the clavicle hook plate, determine whether there is subacromial impingement caused by hook plate fixation, and evaluate the mechanical strength of...
4.
Ruder J, Dickinson E, Peindl R, Habet N, Trofa D, Fleischli J
Arthroscopy . 2019 Apr; 35(7):1954-1959.e4. PMID: 30979619
Purpose: To evaluate the cyclic displacement and ultimate load to failure of 4 all-suture anchors in human cadaveric shoulder glenoid bone. Methods: Four all-suture anchors indicated for glenoid labral repair...
5.
Ruder J, Dickinson E, Peindl R, Habet N, Fleischli J
Arthroscopy . 2018 Sep; 34(10):2777-2781. PMID: 30195950
Purpose: To evaluate the effect of greater tuberosity decortication on ultimate load to failure and displacement after cyclic loading with an all-suture anchor. Methods: A 2.9-mm all-suture anchor was evaluated...
6.
Newman M, Hirsch M, Peindl R, Habet N, Tsai T, Runyon M, et al.
Gait Posture . 2018 May; 63:248-253. PMID: 29778065
Background: Studies have evaluated the test-re-test reliability of subcomponents of the timed up and-go test in adults by using body-worn inertial sensors. However, studies in children have not been reported...
7.
Ruder J, Dickinson E, Habet N, Peindl R, DAlessandro D, Fleischli J
Arthroscopy . 2018 Feb; 34(5):1384-1390. PMID: 29456066
Purpose: To determine if the depth of anchor insertion affects the biomechanical performance of a 1.5-mm all-suture anchor in glenoid bone. Methods: A 1.5-mm all-suture anchor was tested in 8...
8.
Jennings J, Leas D, Fleischli J, DAlessandro D, Peindl R, Piasecki D
Orthop J Sports Med . 2017 Aug; 5(8):2325967117719857. PMID: 28840144
Background: Improved biomechanical and clinical outcomes are seen when the femoral tunnels of the anterior cruciate ligament (ACL) are placed in the center of the femoral insertion. The transtibial (TT)...
9.
Kuremsky M, Habet N, Peindl R, Gaston R
Arthroscopy . 2016 Sep; 32(12):2490-2494. PMID: 27614390
Purpose: To quantify the distance of the dorsal ulnar sensory branch, floor of the extensor carpi ulnaris (ECU) subsheath, and ulnar neurovascular bundles from the triangular fibrocartilage complex (TFCC), and...
10.
Hicks-Little C, Peindl R, Hubbard-Turner T, Cordova M
J Sport Rehabil . 2016 Jul; 25(3):213-8. PMID: 27445119
Context: Knee osteoarthritis (OA) is a debilitating disease that affects an estimated 27 million Americans. Changes in lower-extremity alignment and joint laxity have been found to redistribute the medial and/or...