Recent Articles
1.
Jabbari K, Pashaei F, Ay M, Amouheidari A, Tavakoli M
J Med Signals Sens . 2018 Mar; 8(1):31-38. PMID: 29535922
Background: MapCHECK2 is a two-dimensional diode arrays planar dosimetry verification system. Dosimetric results are evaluated with gamma index. This study aims to provide comprehensive information on the impact of various...
2.
Sharifpour R, Ghafarian P, Rahmim A, Ay M
Nucl Med Commun . 2017 Sep; 38(11):948-955. PMID: 28863124
Objective: The aim of this study was to investigate the impact of time-of-flight (TOF) on quantification and reduction of respiratory artifacts. Patients And Methods: The National Electrical Manufacturers Association phantom...
3.
Sajedi S, Kamal Asl A, Ay M, Farahani M, Rahmim A
Med Eng Phys . 2012 Sep; 35(6):754-64. PMID: 22964063
Applications in imaging and spectroscopy rely on pulse processing methods for appropriate data generation. Often, the particular method utilized does not highly impact data quality, whereas in some scenarios, such...
4.
Ay M, Mehranian A, Abdoli M, Ghafarian P, Zaidi H
Mol Imaging Biol . 2011 Jan; 13(6):1077-87. PMID: 21203854
Purpose: We evaluate the magnitude of metallic artifacts caused by various implantable cardiac pacing devices (without leads) on both attenuation maps (μ-maps) and positron emission tomography (PET) images using experimental...
5.
Ghafarian P, Aghamiri S, Ay M, Rahmim A, Schindler T, Ratib O, et al.
Eur J Nucl Med Mol Imaging . 2010 Oct; 38(2):252-62. PMID: 20959974
Purpose: Cardiac PET/CT imaging is often performed in patients with pacemakers and implantable cardioverter defibrillator (ICD) leads. However, metallic implants usually produce artefacts on CT images which might propagate to...
6.
Ay M, Shirmohammad M, Sarkar S, Rahmim A, Zaidi H
Mol Imaging Biol . 2010 Apr; 13(1):187-98. PMID: 20387123
Introduction: Reliable quantification in positron emission tomography (PET) requires accurate attenuation correction of emission data, which in turn entails accurate determination of the attenuation map (µ-map) of the object under...
7.
Ahmadian A, Ay M, Bidgoli J, Sarkar S, Zaidi H
Eur J Nucl Med Mol Imaging . 2008 Apr; 35(10):1812-23. PMID: 18418597
Purpose: Oral contrast is usually administered in most X-ray computed tomography (CT) examinations of the abdomen and the pelvis as it allows more accurate identification of the bowel and facilitates...