» Authors » Matthias Schmand

Matthias Schmand

Explore the profile of Matthias Schmand including associated specialties, affiliations and a list of published articles. Areas
Snapshot
Articles 8
Citations 415
Followers 0
Related Specialties
Top 10 Co-Authors
Published In
Affiliations
Soon will be listed here.
Recent Articles
1.
Schmidt F, Allen M, Ladebeck R, Breuer J, Judenhofer M, Schmand M, et al.
Med Phys . 2023 Dec; 51(2):991-1006. PMID: 38150577
Background: Simultaneous positron emission tomography (PET)/magnetic resonance imaging (MRI) scanners and inserts are valuable tools for accurate diagnosis, treatment planning, and monitoring due to their complementary information. However, the integration...
2.
Jiang J, Samanta S, Li K, Siegel S, Mintzer R, Cho S, et al.
IEEE Trans Med Imaging . 2020 Jan; 39(11):3268-3277. PMID: 31899415
A novel technique, called augmented whole-body scanning via magnifying PET (AWSM-PET), that improves the sensitivity and lesion detectability of a PET scanner for whole-body imaging is proposed and evaluated. A...
3.
Eric Berg , Zhang X, Bec J, Judenhofer M, Patel B, Peng Q, et al.
J Nucl Med . 2018 Feb; 59(6):993-998. PMID: 29419483
We describe a long axial field-of-view (FOV) PET scanner for high-sensitivity and total-body imaging of nonhuman primates and present the physical performance and first phantom and animal imaging results. The...
4.
Kolb A, Wehrl H, Hofmann M, Judenhofer M, Eriksson L, Ladebeck R, et al.
Eur Radiol . 2012 Jul; 22(8):1776-88. PMID: 22752524
Objectives: Technical performance evaluation of a human brain PET/MRI system. Methods: The magnetic field compatible positron emission tomography (PET) insert is based on avalanche photodiode (APD) arrays coupled with lutetium...
5.
Cho S, Grazioso R, Zhang N, Aykac M, Schmand M
Phys Med Biol . 2011 Nov; 56(23):7569-83. PMID: 22086164
The main focus of our study is to investigate how the performance of digital timing methods is affected by sampling rate, anti-aliasing and signal interpolation filters. We used the Nyquist...
6.
Catana C, Benner T, van der Kouwe A, Byars L, Hamm M, Chonde D, et al.
J Nucl Med . 2010 Dec; 52(1):154-61. PMID: 21189415
Unlabelled: Head motion is difficult to avoid in long PET studies, degrading the image quality and offsetting the benefit of using a high-resolution scanner. As a potential solution in an...
7.
Catana C, van der Kouwe A, Benner T, Michel C, Hamm M, Fenchel M, et al.
J Nucl Med . 2010 Sep; 51(9):1431-8. PMID: 20810759
Unlabelled: Several factors have to be considered for implementing an accurate attenuation-correction (AC) method in a combined MR-PET scanner. In this work, some of these challenges were investigated, and an...
8.
Schlemmer H, Pichler B, Schmand M, Burbar Z, Michel C, Ladebeck R, et al.
Radiology . 2008 Aug; 248(3):1028-35. PMID: 18710991
The purpose of this study was to apply a magnetic resonance (MR) imaging-compatible positron emission tomographic (PET) detector technology for simultaneous MR/PET imaging of the human brain and skull base....