» Authors » Matthew J Kraay

Matthew J Kraay

Explore the profile of Matthew J Kraay including associated specialties, affiliations and a list of published articles. Areas
Snapshot
Articles 37
Citations 437
Followers 0
Related Specialties
Top 10 Co-Authors
Published In
Affiliations
Soon will be listed here.
Recent Articles
1.
Bigach S, Kolevar M, Moore R, Adavi P, Rimnac C, Kraay M
HSS J . 2023 Feb; 19(1):69-76. PMID: 36776510
The Epoch FullCoat Hip Stem (Zimmer) was an isoelastic composite femoral stem developed to address stem stiffness concerns. : We sought to evaluate the long-term bone mineral density (BMD) of...
2.
Pronovost P, Ata G, Carson B, Gordon Z, Smith G, Khaitan L, et al.
Popul Health Manag . 2022 Mar; 25(4):561-567. PMID: 35231195
No abstract available.
3.
Yakkanti R, Ocksrider J, Patel A, Kolevar M, Moore R, Rimnac C, et al.
J Arthroplasty . 2022 Feb; 37(6):1130-1135. PMID: 35131388
Background: A uniquely designed, non-heat-treated moderately cross-linked acetabular polyethylene liner used in total hip arthroplasty (THA) demonstrated excessive wear during routine follow-up, prompting an evaluation of the linear wear rate....
4.
Su C, Copp J, Weinberg D, Kraay M, Fitzgerald S, Wera G
J Knee Surg . 2019 Mar; 33(6):603-610. PMID: 30921820
Readmission within 90 days following total joint arthroplasty has become a central quality measure of reimbursement initiatives; however, the validity of readmission rates as a measure of hospital care quality...
5.
Fitzgerald S, Palmer T, Kraay M
J Arthroplasty . 2018 Apr; 33(8):2387-2391. PMID: 29691166
Background: We developed an orthopedic hospitalist fellowship program for our total joint replacement program at a large urban academic medical center. The goal of the program was to improve patient...
6.
Parran K, Bechtel C, Moore R, Gebhart J, Reich M, Kraay M, et al.
J Arthroplasty . 2018 Apr; 33(8):2677-2683. PMID: 29681493
Background: All polyethylene acetabular liners wear over time, and numerous methods for calculating linear wear rates exist. The objective of this study was to compare 2-dimensional wear rates between direct,...
7.
Morrison T, Moore R, Meng J, Rimnac C, Kraay M
HSS J . 2018 Feb; 14(1):60-66. PMID: 29398997
Background: Concerns have arisen regarding deterioration of wear properties of yttria-stabilized zirconia (YSZ) femoral head on conventional polyethylene (PE) bearings due to YSZ phase transformation. Questions/purposes: The purpose of this...
8.
MacDonald D, Chen A, Lee G, Klein G, Mont M, Kurtz S, et al.
J Arthroplasty . 2017 Jul; 32(9):2887-2891. PMID: 28668212
Background: During revision surgery with a well-fixed stem, a titanium sleeve can be used in conjunction with a ceramic head to achieve better stress distribution across the taper surface. In ...
9.
Arnholt C, MacDonald D, Underwood R, Guyer E, Rimnac C, Kurtz S, et al.
J Arthroplasty . 2017 Jan; 32(4):1363-1373. PMID: 28111124
Background: Previous studies identified imprinting of the stem morphology onto the interior head bore, leading researchers to hypothesize an influence of taper topography on mechanically assisted crevice corrosion. The purpose...
10.
Weinberg D, Kraay M, Fitzgerald S, Sidagam V, Wera G
Clin Orthop Relat Res . 2016 Nov; 475(5):1414-1423. PMID: 27837400
Background: Readmissions after total joint arthroplasty have become a key quality measure in elective surgery in the United States. The Affordable Care Act includes the Hospital Readmission Reduction Program, which...