Marcin Guzinski
Overview
Explore the profile of Marcin Guzinski including associated specialties, affiliations and a list of published articles.
Author names and details appear as published. Due to indexing inconsistencies, multiple individuals may share a name, and a single author may have variations. MedLuna displays this data as publicly available, without modification or verification
Snapshot
Snapshot
Articles
11
Citations
63
Followers
0
Related Specialties
Related Specialties
Top 10 Co-Authors
Top 10 Co-Authors
Published In
Published In
Affiliations
Affiliations
Soon will be listed here.
Recent Articles
1.
Guzinski M, Lindner E, Pendley B, Chaum E
Talanta
. 2021 Dec;
239:123072.
PMID: 34864535
Amitriptyline and its metabolite, Nortriptyline are commonly used tricyclic antidepressant (TCA) drugs that are electrochemically active. In this work, the performance characteristics of a plasticized PVC membrane-coated glassy carbon (GC)...
2.
Guzinski M, Lindner E, Pendley B, Chaum E
Anal Chim Acta
. 2021 Jun;
1171:338642.
PMID: 34112432
Thin plasticized PVC membrane-coated glassy carbon working electrodes have been used for the voltammetric measurement of highly lipophilic, electroactive drugs. Compared to conventional working electrodes, these membrane-coated electrodes exhibit remarkable...
3.
Hambly B, Sears C, Guzinski M, Perez F, Latonen R, Bobacka J, et al.
Langmuir
. 2020 Dec;
37(1):499-508.
PMID: 33372781
To assess the feasibility of utilizing reagent-loaded, porous polymeric nanocapsules (NCs) for chemical and biochemical sensor design, the surfaces of the NCs were decorated with 3,4-ethylenedioxythiophene (EDOT) moieties. The pores...
4.
Lindner E, Guzinski M, Pendley B, Chaum E
Membranes (Basel)
. 2020 Sep;
10(9).
PMID: 32867276
In the last 50 years, plasticized polyvinyl chloride (PVC) membranes have gained unique importance in chemical sensor development. Originally, these membranes separated two solutions in conventional ion-selective electrodes. Later, the...
5.
Hambly B, Guzinski M, Pendley B, Lindner E
ACS Sens
. 2020 Jun;
5(7):2146-2154.
PMID: 32560587
The theoretical models for ISEs almost exclusively assume thermodynamic equilibrium at the membrane/solution-phase boundary. In this report, we present a new, congruent model which combines first-order reaction kinetics of ion-exchange...
6.
Lindner E, Guzinski M, Khan T, Pendley B
ACS Sens
. 2019 Feb;
4(3):549-561.
PMID: 30762347
In this paper, we raise questions that researchers have to ask if they intend to replace a conventional reference electrode with an ionic liquid-based reference electrode and try to answer...
7.
Guzinski M, Jarvis J, DOrazio P, Izadyar A, Pendley B, Lindner E
Anal Chem
. 2017 Jul;
89(16):8468-8475.
PMID: 28691799
The aim of this study was to find a conducting polymer-based solid contact (SC) for ion-selective electrodes (ISEs) that could become the ultimate, generally applicable SC, which in combination with...
8.
Guzinski M, Jarvis J, Perez F, Pendley B, Lindner E, De Marco R, et al.
Anal Chem
. 2017 Feb;
89(6):3508-3516.
PMID: 28194968
To understand the rate determining processes during the equilibration of poly(3,4-ethylenedioxythiophene):polystyrenesulfonate-based (PEDOT(PSS)-based) solid contact (SC) ion-selective electrodes (ISEs), the surfaces of Pt, Au, and GC electrodes were coated with 0.1,...
9.
Guzinski M, Jarvis J, Pendley B, Lindner E
Anal Chem
. 2015 May;
87(13):6654-9.
PMID: 26005770
Papers published on ion-selective electrodes (ISEs) generally report on the performance characteristics of these devices after long, extensive conditioning. Conditioning refers to the equilibration of the ion-selective electrode in an...
10.
Guzinski M, Lisak G, Kupis J, Jasinski A, Bochenska M
Anal Chim Acta
. 2013 Jul;
791:1-12.
PMID: 23890601
In potentiometry, high selectivity of the ion-selective membranes must be assured in order to reliably measure various analytes in clinical, industrial and environmental samples. Due to the toxic nature of...