Luis A Benevides
Overview
Explore the profile of Luis A Benevides including associated specialties, affiliations and a list of published articles.
Author names and details appear as published. Due to indexing inconsistencies, multiple individuals may share a name, and a single author may have variations. MedLuna displays this data as publicly available, without modification or verification
Snapshot
Snapshot
Articles
6
Citations
22
Followers
0
Related Specialties
Related Specialties
Top 10 Co-Authors
Top 10 Co-Authors
Published In
Published In
Affiliations
Affiliations
Soon will be listed here.
Recent Articles
1.
Romanyukha A, Grypp M, Sharp T, DiRito J, Nelson M, Mavrogianis S, et al.
Health Phys
. 2018 Mar;
114(5):543-548.
PMID: 29578903
The U.S. Navy uses the Harshaw 8840/8841 dosimetric (DT-702/PD) system, which employs LiF:Mg,Cu,P thermoluminescent dosimeters (TLDs), developed and produced by Thermo Fisher Scientific (TFS). The dosimeter consists of four LiF:Mg,Cu,P...
2.
Romanyukha A, Trompier F, Benevides L
Health Phys
. 2016 Jun;
111(2):127-33.
PMID: 27356056
Today the armed forces and law enforcement personnel wear body armor, helmets, and flak jackets composed substantially of Kevlar® fiber to prevent bodily injury or death resulting from physical, ballistic,...
3.
Romanyukha A, Reyes R, Trompier F, Benevides L
Health Phys
. 2010 Jan;
98(2):296-300.
PMID: 20065697
A summary of recent developments in fingernail EPR dosimetry is presented in this paper. Until 2007, there had been a very limited number of studies of radiation-induced signals in fingernails....
4.
Romanyukha A, King D, Benevides L
Radiat Prot Dosimetry
. 2008 May;
131(2):180-7.
PMID: 18448436
An extension of dosemeter issue period brings significant economic and logistic benefits. Therefore, it is desirable to have an extended period as long as possible without significant loss of the...
5.
Benevides L, Huston A, Justus B, Falkenstein P, Brateman L, Hintenlang D
Med Phys
. 2007 Jul;
34(6):2220-7.
PMID: 17654923
Fiber-optic-coupled radioluminescent (FOC) dosimeters are members of a new family of dosimeters that are finding increased clinical applications. This study provides the first characterization of a Cu doped quartz FOC...
6.
Benevides L, Hintenlang D
Med Phys
. 2006 Mar;
33(2):514-20.
PMID: 16532959
Five high-sensitivity metal oxide semiconductor field effect transistor dosimeters in the TN-502 and 1002 series (Thomson Nielsen Electronics Ltd., 25B, Northside Road, Ottawa, ON K2H8S1, Canada) were evaluated for use...