Ludivine Wissocque
Overview
Explore the profile of Ludivine Wissocque including associated specialties, affiliations and a list of published articles.
Author names and details appear as published. Due to indexing inconsistencies, multiple individuals may share a name, and a single author may have variations. MedLuna displays this data as publicly available, without modification or verification
Snapshot
Snapshot
Articles
13
Citations
82
Followers
0
Related Specialties
Related Specialties
Top 10 Co-Authors
Top 10 Co-Authors
Published In
Published In
Affiliations
Affiliations
Soon will be listed here.
Recent Articles
1.
Wahbi K, Babuty D, Probst V, Wissocque L, Labombarda F, Porcher R, et al.
Eur Heart J
. 2016 Dec;
38(10):751-758.
PMID: 27941019
Aims: To describe the incidence and identify predictors of sudden death (SD), major conduction defects and sustained ventricular tachyarrhythmias (VTA) in myotonic dystrophy type 1 (DM1). Methods And Results: We...
2.
Wissocque L, Mondesert B, Dubart A
Eur J Cardiothorac Surg
. 2015 Nov;
49(5):1524-5.
PMID: 26574496
We report the case of a 92-year old woman with congenitally corrected transposition of the great arteries (CCTGA). The case is remarkable as the CCTGA had remained undiagnosed until the...
3.
Souissi Z, Guedon-Moreau L, Boule S, Kouakam C, Finat L, Marquie C, et al.
Europace
. 2015 Oct;
18(6):820-7.
PMID: 26498163
Aims: Lead fractures in implantable cardioverter-defibrillator (ICD) patients may cause inappropriate shocks (ISs). An early diagnosis is essential to prevent adverse clinical events. Implantable cardioverter-defibrillator remote monitoring (RM) permits prompt...
4.
Wissocque L, Klein C, Marquie C, Klug D
J Vasc Access
. 2015 Oct;
17(1):e10-1.
PMID: 26450083
No abstract available.
5.
Guedon-Moreau L, Finat L, Boule S, Wissocque L, Marquie C, Brigadeau F, et al.
Circ Cardiovasc Qual Outcomes
. 2015 Jun;
8(4):403-12.
PMID: 26105725
Background: Implantable cardioverter-defibrillators (ICDs) are a standard means of sudden cardiac death prevention. Compared with ambulatory visits, remote monitoring (RM) of ICD recipients has improved the quality of health care...
6.
Wissocque L, Brigadeau F, Richardson M, Boule S, Kouakam C, Polge A, et al.
Int J Cardiol
. 2015 May;
191:46-7.
PMID: 25965595
No abstract available.
7.
Wissocque L, Aucouturier J, Mondesert B, Chague F, Duva Pentiah A, Simeone A, et al.
Int J Cardiol
. 2014 Dec;
179:20-2.
PMID: 25464397
No abstract available.
8.
Morichau-Beauchant T, Boule S, Guedon-Moreau L, Finat L, Botcherby E, Perier M, et al.
Arch Cardiovasc Dis
. 2014 Sep;
107(12):664-71.
PMID: 25241223
Background: Remote monitoring (RM) is increasingly used to follow up patients with implantable cardioverter-defibrillators (ICDs). Randomized control trials provide evidence for the benefit of this intervention, but data for RM...
9.
Boule S, Ouadah A, Langlois C, Botcherby E, Verbrugge E, Huchette D, et al.
Can J Cardiol
. 2014 Jun;
30(6):606-11.
PMID: 24882530
Background: For patients presenting with syncope and bundle branch block (BBB), results during electrophysiological studies (EPS) might depend on the electrocardiographic pattern of conduction disturbances. We sought to identify predictors...
10.
Boule S, Ovart L, Marquie C, Botcherby E, Klug D, Kouakam C, et al.
Europace
. 2014 Mar;
16(11):1587-94.
PMID: 24596396
Aims: To describe obstetric/neonatal and cardiac outcomes for a cohort of women carrying implantable cardioverter-defibrillators (ICDs) during pregnancy. Methods And Results: All women in routine follow-up at our institution for...