» Authors » Loren W Nolte

Loren W Nolte

Explore the profile of Loren W Nolte including associated specialties, affiliations and a list of published articles. Areas
Snapshot
Articles 12
Citations 88
Followers 0
Related Specialties
Top 10 Co-Authors
Published In
Affiliations
Soon will be listed here.
Recent Articles
1.
Kiarashi N, Nolte L, Lo J, Segars W, Ghate S, Solomon J, et al.
J Med Imaging (Bellingham) . 2016 Sep; 3(3):035504. PMID: 27660807
This study aims to characterize the effect of background tissue density and heterogeneity on the detection of irregular masses in breast tomosynthesis, while demonstrating the capability of the sophisticated tools...
2.
Kiarashi N, Nolte A, Sturgeon G, Segars W, Ghate S, Nolte L, et al.
Med Phys . 2015 Jul; 42(7):4116-26. PMID: 26133612
Purpose: Physical phantoms are essential for the development, optimization, and evaluation of x-ray breast imaging systems. Recognizing the major effect of anatomy on image quality and clinical performance, such phantoms...
3.
Kiarashi N, Lo J, Lin Y, Ikejimba L, Ghate S, Nolte L, et al.
IEEE Trans Med Imaging . 2014 Apr; 33(7):1401-9. PMID: 24691118
Mammography is currently the most widely utilized tool for detection and diagnosis of breast cancer. However, in women with dense breast tissue, tissue overlap may obscure lesions. Digital breast tomosynthesis...
4.
Barr R, Nolte L, Pollard A
IEEE Rev Biomed Eng . 2012 Jan; 3:155-68. PMID: 22275206
Bayesian interpretation of observations began in the early 1700s, and scientific electrophysiology began in the late 1700s. For two centuries these two fields developed mostly separately. In part that was...
5.
Chen B, Shorey J, Saunders Jr R, Richard S, Thompson J, Nolte L, et al.
Acad Radiol . 2011 Mar; 18(5):536-46. PMID: 21397528
Rationale And Objectives: Optimization studies for x-ray-based breast imaging systems using computer simulation can greatly benefit from a phantom capable of modeling varying anatomical variability across different patients. This study...
6.
Qian M, Aguilar M, Zachery K, Privitera C, Klein S, Carney T, et al.
IEEE Trans Biomed Eng . 2009 Apr; 56(7):1929-37. PMID: 19336285
Several recent studies have reported success in applying EEG-based signal analysis to achieve accurate single-trial classification of responses to visual target detection. Pupil responses are proposed as a complementary modality...
7.
Barr R, Nolte L, Pollard A
Annu Int Conf IEEE Eng Med Biol Soc . 2007 Nov; 2007:423-9. PMID: 18001980
The resistivities of microscale components of excitable tissue include the longitudinal intracellular and interstitial resistivities and the membrane resistivity. Measurements of these tissue micro impedances have rarely been obtained, mainly...
8.
Jesneck J, Nolte L, Baker J, Floyd C, Lo J
Med Phys . 2006 Sep; 33(8):2945-54. PMID: 16964873
As more diagnostic testing options become available to physicians, it becomes more difficult to combine various types of medical information together in order to optimize the overall diagnosis. To improve...
9.
Sha L, Nolte L
J Acoust Soc Am . 2005 May; 117(4 Pt 1):1954-64. PMID: 15898640
The detection performance of sonar systems can be greatly limited by the presence of interference and environmental uncertainty. The classic sonar equation does not take into account these two limiting...
10.
Sha L, Nolte L
J Acoust Soc Am . 2005 May; 117(4 Pt 1):1942-53. PMID: 15898639
The development of effective passive sonar systems depends upon the ability to accurately predict the performance of sonar detection algorithms in realistic ocean environments. Such environments are typically characterized by...