» Authors » Kenneth D Kihm

Kenneth D Kihm

Explore the profile of Kenneth D Kihm including associated specialties, affiliations and a list of published articles. Areas
Snapshot
Articles 19
Citations 117
Followers 0
Related Specialties
Top 10 Co-Authors
Published In
Affiliations
Soon will be listed here.
Recent Articles
11.
Choi C, Margraves C, English A, Kihm K
J Biomed Opt . 2008 Nov; 13(5):054069. PMID: 19021447
Multicontrast microscopy techniques were used to comprehensively and dynamically map the cellular contact area adhering to a substrate. The natural fringe patterns observed with interference reflection contrast microscopy were used...
12.
Kim S, English A, Kihm K
Acta Biomater . 2008 Sep; 5(1):144-51. PMID: 18774763
The surface micromechanical properties of 2-hydroxyethyl methacrylate (HEMA) and 2-methacryloxyethyl trimethyl ammonium chloride (MAETAC) copolymer hydrogels are probed using atomic force microscopy. HEMA-MAETAC polyelectrolyte hydrogels with increasing positive charge concentrations...
13.
Kim I, Kihm K
Langmuir . 2008 Sep; 25(4):1881-4. PMID: 18759414
The existence of hidden complex cavities formed inside a self-assembled nanocrystalline structure is discovered in real-time by using surface plasmon resonance near-field refractive index fingerprinting. Furthermore, computer analysis of the...
14.
Choi C, English A, Kihm K, Margraves C
J Biomed Opt . 2008 Jan; 12(6):064028. PMID: 18163844
This study quantifies the dynamic attachment and spreading of porcine pulmonary artery endothelial cells (PPAECs) on optically thin, indium tin oxide (ITO) biosensors using simultaneous differential interference contrast microscopy (DICM)...
15.
Kim I, Kihm K
Anal Chem . 2007 Jun; 79(14):5418-23. PMID: 17566981
An idea of real-time and full-field detection of near-wall salinity is presented to use the surface plasmon resonance (SPR) reflectance that changes with refractive index variations of the tested saline...
16.
Choi C, Kihm K, English A
Opt Lett . 2007 Jun; 32(11):1405-7. PMID: 17546136
The use of an optically thin indium-tin-oxide (ITO) electrode is presented for an optoelectric biosensor simultaneously recording optical images and microimpedance to examine time-dependent cellular growth. The transmittance of a...
17.
Chon C, Paik S, Tipton Jr J, Kihm K
Langmuir . 2007 Mar; 23(6):2953-60. PMID: 17338500
A microfabricated linear heater array operating in a constant voltage mode has been used to study the effect of nanoparticle size on the evaporation and dryout characteristics of strongly pinned...
18.
Choi C, English A, Jun S, Kihm K, Rack P
Biosens Bioelectron . 2006 Nov; 22(11):2585-90. PMID: 17113768
This study describes the fabrication and performance of an endothelial cell compatible, optically thin, indium tin oxide (ITO) microimpedance biosensor. The biosensor was constructed by sputtering a thin insulating layer...
19.
Banerjee A, Kihm K
Phys Rev E Stat Nonlin Soft Matter Phys . 2005 Dec; 72(4 Pt 1):042101. PMID: 16383445
A total internal reflection fluorescence microscopy technique coupled with three-dimensional tracking of nanoparticles is used to experimentally verify the theory on near-wall hindered Brownian motion [Goldman et al., Chem. Eng....