» Authors » Joerg Roland

Joerg Roland

Explore the profile of Joerg Roland including associated specialties, affiliations and a list of published articles. Areas
Snapshot
Articles 7
Citations 92
Followers 0
Related Specialties
Top 10 Co-Authors
Published In
Affiliations
Soon will be listed here.
Recent Articles
1.
Rosenberg C, Kickhefel A, Mensel B, Pickartz T, Puls R, Roland J, et al.
PLoS One . 2013 Nov; 8(10):e78559. PMID: 24205260
Objective: To compare the accuracy of a semi-quantitative proton resonance frequency shift (PRFS) thermal mapping interface and an alternative qualitative T1 thermometry model in predicting tissue necrosis in an established...
2.
Auboiroux V, Viallon M, Roland J, Hyacinthe J, Petrusca L, Morel D, et al.
Magn Reson Med . 2012 Jan; 68(3):932-46. PMID: 22246646
MR acoustic radiation force imaging (ARFI) is an elegant adjunct to MR-guided high intensity focused ultrasound for treatment planning and optimization, permitting in situ assessment of the focusing and targeting...
3.
Salomir R, Viallon M, Kickhefel A, Roland J, Morel D, Petrusca L, et al.
IEEE Trans Med Imaging . 2011 Sep; 31(2):287-301. PMID: 21937345
Proton resonance frequency shift (PRFS) MR thermometry (MRT) is the generally preferred method for monitoring thermal ablation, typically implemented with gradient-echo (GRE) sequences. Standard PRFS MRT is based on the...
4.
Kickhefel A, Weiss C, Roland J, Gross P, Schick F, Salomir R
MAGMA . 2011 Sep; 25(1):23-31. PMID: 21898135
Introduction: The susceptibility contrast between frozen and unfrozen tissue disturbs the local magnetic field in the proximity of the ice-ball during cryotherapy. This effect should be corrected for in real...
5.
Kickhefel A, Rosenberg C, Weiss C, Rempp H, Roland J, Schick F, et al.
J Magn Reson Imaging . 2011 May; 33(3):704-12. PMID: 21563256
Purpose: To assess the feasibility, precision, and accuracy of real-time temperature mapping (TMap) during laser-induced thermotherapy (LITT) for clinical practice in patients liver with a gradient echo (GRE) sequence using...
6.
Viallon M, Terraz S, Roland J, Dumont E, Becker C, Salomir R
Med Phys . 2010 May; 37(4):1491-506. PMID: 20443470
Purpose: MR thermometry based on the proton resonance frequency shift (PRFS) is the most commonly used method for the monitoring of thermal therapies. As the chemical shift of water protons...
7.
Cernicanu A, Lepetit-Coiffe M, Roland J, Becker C, Terraz S
NMR Biomed . 2008 Jun; 21(8):849-58. PMID: 18574794
The purpose of this work was to validate in phantom studies and demonstrate the clinical feasibility of MR proton resonance frequency thermometry at 1.5 T with segmented gradient-echo echo planar...