Joachim Kron
Overview
Explore the profile of Joachim Kron including associated specialties, affiliations and a list of published articles.
Author names and details appear as published. Due to indexing inconsistencies, multiple individuals may share a name, and a single author may have variations. MedLuna displays this data as publicly available, without modification or verification
Snapshot
Snapshot
Articles
21
Citations
79
Followers
0
Related Specialties
Related Specialties
Top 10 Co-Authors
Top 10 Co-Authors
Published In
Affiliations
Affiliations
Soon will be listed here.
Recent Articles
1.
Kron J, Volkenandt J, Broszeit S, Leimbach T, Kron S
Hemodial Int
. 2025 Mar;
PMID: 40044573
Introduction: Under physiological conditions, blood volume and extracellular volume are in a ratio of 1-3, even in hemodialysis patients. The question therefore arises: can blood volume be inferred from the...
2.
Kron J, Broszeit S, Leimbach T, Kron S
Int J Artif Organs
. 2024 Nov;
47(12):939-942.
PMID: 39511830
Current online hemodiafiltration devices can be used to determine the absolute blood volume in clinical practice using the dialysate bolus method. Most of publications on this method have focused on...
3.
Broszeit S, Kron J, Leimbach T, Volkenandt J, Kron S
Int J Artif Organs
. 2024 Aug;
47(10):723-728.
PMID: 39097793
Background: The rate and the duration of ultrafiltration (UF) are considered the most important factors to affect vascular refilling. The aim of the study was to investigate whether a UF...
4.
Kron J, Kron S
ASAIO J
. 2024 Aug;
PMID: 39088725
Absolute blood volume can be calculated from the increase in relative blood volume after an infusion of a well-defined volume bolus of ultrapure dialysate into the extracorporeal circulation. Several working...
5.
Kron J, Broszeit S, Volkenandt J, Leimbach T, Kron S
Int J Artif Organs
. 2023 Sep;
46(10-11):581-584.
PMID: 37749906
The ratio of blood volume to extracellular volume is approximately one to three under physiological conditions and also in stable chronic hemodialysis patients. Recently, it was found that this ratio...
6.
Kron S, Schneditz D, Leimbach T, Schneider J, Kron J
Hemodial Int
. 2022 Jun;
26(4):540-547.
PMID: 35711103
Introduction: Long dialysis treatments are generally assumed to mitigate the ultrafiltration (UF) induced volume perturbation and to improve vascular refilling because of reduced UF rates and sufficient time for volume...
7.
Kron S, Schneditz D, Kron J
Nephrol Dial Transplant
. 2022 Apr;
37(10):2034-2036.
PMID: 35425989
No abstract available.
8.
Kron S, Schneditz D, Keane D, Leimbach T, Kron J
Artif Organs
. 2021 Apr;
45(9):E359-E363.
PMID: 33908065
Online hemodiafiltration machines equipped with a blood volume monitor and the possibility to rapidly infuse exact amounts of ultrapure dialysate into the extracorporeal circulation can be used to determine absolute...
9.
Kron S, Schneditz D, Leimbach T, Kron J
Hemodial Int
. 2020 Mar;
24(3):344-350.
PMID: 32115891
Introduction: The success of automatic feedback control systems to improve hemodynamic stability by preventing relative blood volume from dropping beyond a critical value during dialysis is limited. The aim of...
10.
Schneditz D, Kron J, Hecking M
ASAIO J
. 2018 Oct;
64(6):697-700.
PMID: 30281545
No abstract available.