Recent Articles
1.
Zhang X, Xie J, Tan Y, Su T, Zhu J, Cui H, et al.
Med Phys
. 2024 Dec;
52(3):1500-1514.
PMID: 39688364
Background: Recently, the popularity of dual-layer flat-panel detector (DL-FPD) based dual-energy cone-beam CT (CBCT) imaging has been increasing. However, the image quality of dual-energy CBCT remains constrained by the Compton...
2.
Zhu J, Zhang X, Su T, Cui H, Tan Y, Huang H, et al.
Med Phys
. 2024 Nov;
52(2):771-786.
PMID: 39556663
Background: Multi-material decomposition is an interesting topic in dual-energy CT (DECT) imaging; however, the accuracy and performance may be limited using the conventional algorithms. Purpose: In this work, a novel...
3.
Zhang X, Xie J, Su T, Zhu J, Xia D, Zheng H, et al.
Phys Med Biol
. 2024 Oct;
69(21).
PMID: 39419085
The aim of this study was to investigate the impact of the bowtie filter on the image quality of the photon-counting detector (PCD) based CT imaging.Numerical simulations were conducted to...
4.
Cui H, Su T, Zhang X, Zhu J, Tan Y, Zheng H, et al.
Phys Med Biol
. 2024 Jul;
69(16).
PMID: 39047782
This study aims at developing a simple and rapid Compton scatter correction approach for cone-beam CT (CBCT) imaging.In this work, a new Compton scatter estimation model is established based on...
5.
Liu Y, Gao C, Li D, Zhang X, Zhu J, Wu M, et al.
Nat Commun
. 2024 Feb;
15(1):1588.
PMID: 38383659
High performance X-ray detector with ultra-high spatial and temporal resolution are crucial for biomedical imaging. This study reports a dynamic direct-conversion CMOS X-ray detector assembled with screen-printed CsPbBr, whose mobility-lifetime...
6.
Zhang X, Su T, Zhang Y, Cui H, Tan Y, Zhu J, et al.
Quant Imaging Med Surg
. 2024 Jan;
14(1):640-652.
PMID: 38223035
Background: Recently, deep learning techniques have been widely used in low-dose computed tomography (LDCT) imaging applications for quickly generating high quality computed tomography (CT) images at lower radiation dose levels....
7.
Ma C, Su T, Zhu J, Zhang X, Zheng H, Liang D, et al.
J Xray Sci Technol
. 2024 Jan;
32(1):69-85.
PMID: 38189729
Background: Slow kVp switching technique is an important approach to realize dual-energy CT (DECT) imaging, but its performance has not been thoroughly investigated yet. Objective: This study aims at comparing...
8.
Zhu J, Su T, Zhang X, Cui H, Tan Y, Zheng H, et al.
Phys Med Biol
. 2023 Dec;
69(1).
PMID: 38048627
This study aims at investigating a novel super resolution CBCT imaging approach with a dual-layer flat panel detector (DL-FPD).With DL-FPD, the low-energy and high-energy projections acquired from the top and...
9.
Su T, Zhu J, Zhang X, Tan Y, Cui H, Zeng D, et al.
IEEE Trans Med Imaging
. 2023 Sep;
43(2):734-744.
PMID: 37756176
In flat-panel detector (FPD) based cone-beam computed tomography (CBCT) imaging, the native receptor array is usually binned into a smaller matrix size. By doing so, the signal readout speed could...
10.
Shi T, Liu W, Zhu J, Fan X, Zhang Z, He X, et al.
Nano Res
. 2023 Jun;
:1-7.
PMID: 37359075
Electronic Supplementary Material: Supplementary material (further details of the characterization, SEM images, AFM images, KPFM images, schematic illustration, XRD patterns, XPS spectra, FTIR spectra, UPS spectra, and stability tests) is...