» Authors » H H Hilger

H H Hilger

Explore the profile of H H Hilger including associated specialties, affiliations and a list of published articles. Areas
Snapshot
Articles 217
Citations 477
Followers 0
Related Specialties
Top 10 Co-Authors
Published In
Affiliations
Soon will be listed here.
Recent Articles
1.
Hilger H, Selvi F, Papini A, Bigazzi M
Ann Bot . 2004 Jul; 94(2):201-12. PMID: 15271774
Background And Aims: Boragineae is one of the main tribes of Boraginaceae, but delimitation and intergeneric classification of this group are unclear and have not yet been studied using DNA...
2.
Bohle U, Hilger H, Martin W
Proc Natl Acad Sci U S A . 1996 Oct; 93(21):11740-5. PMID: 8876207
Numerous island-inhabiting species of predominantly herbaceous angiosperm genera are woody shrubs or trees. Such "insular woodiness" is strongly manifested in the genus Echium, in which the continental species of circummediterranean...
3.
Deutsch H, Curtius J, Bongarth C, Behlke E, Borowski A, de Vivie E, et al.
J Heart Valve Dis . 1994 May; 3(3):288-94. PMID: 8087266
Left ventricular geometry and function were assessed in 20 patients with mitral stenosis (MS) and in another 20 patients with mitral insufficiency (MI) five days before and 12 days after...
4.
Sitzler G, Winter U, Peters G, GHEORGHIU T, Hilger H
Dtsch Med Wochenschr . 1994 Mar; 119(12):418-22. PMID: 8143556
A 44-year-old German fell ill in Libya, where he had been living for 10 years, with high fever, rigor and a nonitching centrifugally spreading macular rash, which had spared the...
5.
Winter U, Gitt A, Blaum M, Fritsch J, Berge P, Pothoff G, et al.
Z Kardiol . 1994 Jan; 83 Suppl 3:73-82. PMID: 7941676
Cardiopulmonary exercise testing (CPX) allows a non-invasive control of the cardiopulmonary exercise capacity. In this study, we wanted to investigate if the CPX can be securely, practicably, and accurately performed...
6.
Pothoff G, Wassermann K, Winter U, Geyer D, Hilger H
Z Kardiol . 1994 Jan; 83 Suppl 3:67-71. PMID: 7941675
During steady-state exercise the noninvasive measurement of cardiac output using CO2-rebreathing has been found to be reliable and reproducible. In contrast, reliability of cardiac output measurement during unsteady state exercise...
7.
Gitt A, Winter U, Fritsch J, Pothoff G, Sedlak M, Ehmanns S, et al.
Z Kardiol . 1994 Jan; 83 Suppl 3:37-42. PMID: 7941670
We analyzed 128 cardiopulmonary exercise tests (CPX), performed in normal subjects (n = 31), in patients with coronary artery disease (n = 41), with chronic heart failure before (n =...
8.
Winter U, Fritsch J, Gitt A, Pothoff G, Berge P, Hilger H
Z Kardiol . 1994 Jan; 83 Suppl 3:27-36. PMID: 7941669
The clinician who uses cardio-pulmonary exercise testing (CPX) systems relies on the technical informations from the device producers. In this paper, the practicability, the accuracy and the safety of four...
9.
Pothoff G, Wassermann K, Winter U, Hilger H
Z Kardiol . 1994 Jan; 83 Suppl 3:169-72. PMID: 7941667
Surgical resection for lung cancer provides the only real chance for cure. However, there is a high risk of postoperative complications including death for patients with pulmonary dysfunction. Therefore preoperative...
10.
Wassermann K, Pothoff G, Subbe C, Bahra J, Hilger H
Z Kardiol . 1994 Jan; 83 Suppl 3:149-54. PMID: 7941663
Unlabelled: In 14 patients with obstructive airways disease (7 atopic asthmatics, 7 COPD pts with stable disease, FEV1 < 65% pred., 11 m, 3 f, age 50.9 +/- 17.2 y)...