Franck Jaillon
Overview
Explore the profile of Franck Jaillon including associated specialties, affiliations and a list of published articles.
Author names and details appear as published. Due to indexing inconsistencies, multiple individuals may share a name, and a single author may have variations. MedLuna displays this data as publicly available, without modification or verification
Snapshot
Snapshot
Articles
19
Citations
204
Followers
0
Related Specialties
Related Specialties
Top 10 Co-Authors
Top 10 Co-Authors
Published In
Published In
Affiliations
Affiliations
Soon will be listed here.
Recent Articles
1.
Makita S, Jaillon F, Jahan I, Yasuno Y
Opt Express
. 2014 Mar;
22(4):4830-48.
PMID: 24663800
Noise statistics of phase-resolved optical coherence tomography (OCT) imaging are complicated and involve noises of OCT, correlation of signals, and speckles. In this paper, the statistical properties of phase shift...
2.
Hong Y, Makita S, Jaillon F, Ju M, Min E, Lee B, et al.
Opt Express
. 2012 Feb;
20(3):2740-60.
PMID: 22330511
A high-penetration swept-source optical coherence tomography (HP-SS-OCT) system based on a 1-μm short cavity laser is developed. Doppler OCT processing is applied, along with a custom-made numerical phase stabilization algorithm;...
3.
Makita S, Jaillon F, Yamanari M, Yasuno Y
Opt Express
. 2012 Feb;
20(3):2681-92.
PMID: 22330505
Dual-beam-scan Doppler optical coherence angiography (DB-OCA) enables high-speed, high-sensitivity blood flow imaging. However, birefringence of biological tissues is an obstacle to vasculature imaging. Here, the influence of polarization and birefringence...
4.
Jaillon F, Makita S, Yasuno Y
Opt Express
. 2012 Jan;
20(1):385-96.
PMID: 22274362
In this study, we present dual-beam Doppler optical coherence angiography with variable beam separation. Altering beam distance, independently of the scanning protocol, provides a flexible way to select the velocity...
5.
Jaillon F, Makita S, Min E, Lee B, Yasuno Y
Biomed Opt Express
. 2011 May;
2(5):1147-58.
PMID: 21559127
Dual-beam-scan Doppler optical coherence angiography (DB-OCA) with a 1-μm-wavelength probe is demonstrated for improved in vivo choroidal angiograms of the human eye. This method utilizes two scanning beams with spatial...
6.
Makita S, Jaillon F, Yamanari M, Miura M, Yasuno Y
Opt Express
. 2011 Jan;
19(2):1271-83.
PMID: 21263668
Comprehensive angiography provides insight into the diagnosis of vascular-related diseases. However, complex microvascular networks of unstable in vivo organs such as the eye require micron-scale resolution in three dimensions and...
7.
Jaillon F, Makita S, Yabusaki M, Yasuno Y
Opt Express
. 2010 Feb;
18(2):1358-72.
PMID: 20173963
A full range spectral domain optical coherence tomography (SD-OCT) technique that relies on the linear phase modulation of one of the interferometer arms has been widely utilized. Although this method...
8.
Jaillon F, Li J, Dietsche G, Elbert T, Gisler T
Opt Express
. 2009 Jun;
15(11):6643-50.
PMID: 19546974
Activity of the human visual cortex, elicited by steady-state flickering at 8Hz, is non-invasively probed by multi-speckle diffusingwave spectroscopy (DWS). Parallel detection of the intensity fluctuations of statistically equivalent, but...
9.
Jaillon F, Skipetrov S, Li J, Dietsche G, Maret G, Gisler T
Opt Express
. 2009 Jun;
14(22):10181-94.
PMID: 19529414
We investigate the influence of a non-scattering layer on the temporal field autocorrelation function of multiple scattered light from a multilayer turbid medium such as the human head. Data from...
10.
Li J, Jaillon F, Dietsche G, Maret G, Gisler T
Opt Express
. 2009 Jun;
14(17):7841-51.
PMID: 19529152
We present a technique for measuring transient microscopic dynamics within deep tissue with sub-second temporal resolution, using diffusing-wave spectroscopy with gated single-photon avalanche photodiodes (APDs) combined with standard ungated multi-tau...