» Authors » Emmanuel Schaub

Emmanuel Schaub

Explore the profile of Emmanuel Schaub including associated specialties, affiliations and a list of published articles. Areas
Snapshot
Articles 21
Citations 153
Followers 0
Related Specialties
Top 10 Co-Authors
Published In
Affiliations
Soon will be listed here.
Recent Articles
1.
Schaub E, Ahammou B, Landesman J
Appl Opt . 2022 Feb; 61(6):1307-1315. PMID: 35201011
Anisotropic strain induces a partial linear polarization of the photo-luminescence (PL) emitted by cubic semiconductor crystals such as GaAs or InP. This paper thus presents a polarimetric PL microscope dedicated...
2.
Poryles R, Lenavetier T, Schaub E, Bussonniere A, Saint-Jalmes A, Cantat I
Soft Matter . 2022 Feb; 18(10):2046-2053. PMID: 35195647
Foam film elasticity plays a significant role in film drainage and film stability and is thus expected to influence foam dynamical properties. It strongly depends on the foaming solution composition...
3.
Rouede D, Schaub E, Bellanger J, Ezan F, Tiaho F
Opt Express . 2020 Mar; 28(4):4845-4858. PMID: 32121716
From P-SHG experiments, second-order nonlinear optical anisotropy parameters ρ = χ/χ of collagen tissues are calculated assuming the same model of supercoiled collagen fibril characterized by a variable angle θ....
4.
Rouede D, Schaub E, Bellanger J, Ezan F, Scimeca J, Baffet G, et al.
Sci Rep . 2017 Sep; 7(1):12197. PMID: 28939903
Polarization dependence second harmonic generation (P-SHG) microscopy is gaining increase popularity for in situ quantification of fibrillar protein architectures. In this report, we combine P-SHG microscopy, new linear least square...
5.
Ortega-Quijano N, Fade J, Schaub E, Parnet F, Alouini M
Opt Lett . 2015 Apr; 40(7):1270-3. PMID: 25831310
We report a novel method to unambiguously determine the magnitude and orientation of linear dichroism in a simultaneous way. It is based on the use of a dedicated dual-frequency dual-polarization...
6.
Rouede D, Coumailleau P, Schaub E, Bellanger J, Blanchard-Desce M, Tiaho F
Biomed Opt Express . 2014 Apr; 5(3):858-75. PMID: 24688819
We show that the canonical single frequency sarcomeric SHG intensity pattern (SHG-IP) of control muscles is converted to double frequency sarcomeric SHG-IP in preserved mdx mouse gastrocnemius muscles in the...
7.
Schaub E
Opt Express . 2013 Oct; 21(20):23543-55. PMID: 24104267
We present a fluorescence correlation spectroscopy setup based on a software correlator. The setup can process autocorrelation curves in real-time at countrate as high as 8 MHz, with time resolution...
8.
Rouede D, Bellanger J, Schaub E, Recher G, Tiaho F
Biophys J . 2013 May; 104(9):1959-68. PMID: 23663839
SHG angular intensity pattern (SHG-AIP) of healthy and proteolysed muscle tissues are simulated and imaged here for the first time to our knowledge. The role of the spatial distribution of...
9.
Schaub E
Opt Express . 2012 Feb; 20(3):2184-95. PMID: 22330459
We present a new multiple-tau correlation algorithm which is the fastest to date. The resulting curve is identical to that obtained with the conventional multiple-tau algorithm, but the calculation time...
10.
Rouede D, Recher G, Bellanger J, Lavault M, Schaub E, Tiaho F
Biophys J . 2011 Jul; 101(2):494-503. PMID: 21767503
A theoretical far-field second harmonic generation (SHG) imaging radiation pattern is calculated for muscular myosin taking into account both Gouy effect and light diffraction under high focusing excitation. Theoretical analysis,...