» Authors » David A Armbruster

David A Armbruster

Explore the profile of David A Armbruster including associated specialties, affiliations and a list of published articles. Areas
Snapshot
Articles 9
Citations 846
Followers 0
Related Specialties
Top 10 Co-Authors
Published In
Affiliations
Soon will be listed here.
Recent Articles
1.
Gilmore A, Vu H, Martinez T, Peniata L, Kawaguchi B, Armbruster D, et al.
PLoS One . 2025 Feb; 20(2):e0318487. PMID: 39928650
Laboratory grown biofilms are used to simulate bacterial growth in diverse environmental conditions and screen the effectiveness of anti-biofilm therapies. Recently, we developed a glass bead biofilm reactor that utilizes...
2.
Florek C, Cozzone E, Williams D, Armbruster D
J Biomed Mater Res B Appl Biomater . 2024 Aug; 112(9):e35455. PMID: 39177322
Battlefield wounds are at high risk of infection due to gross contamination and delays in evacuation from forward-deployed locations. The aim of this study was to formulate an antibiotic wound...
3.
Hickok N, Li B, Oral E, Zaat S, Armbruster D, Atkins G, et al.
J Orthop Res . 2023 Dec; 42(3):512-517. PMID: 38146070
Antimicrobial strategies for musculoskeletal infections are typically first developed with in vitro models. The In Vitro Section of the 2023 Orthopedic Research Society Musculoskeletal Infection international consensus meeting (ICM) probed...
4.
Lo Y, Armbruster D
EJIFCC . 2016 Sep; 23(1):5-10. PMID: 27683403
Background: Defining reference intervals is a major challenge because of the difficulty in recruiting volunteers to participate and testing samples from a significant number of healthy reference individuals. Historical literature...
5.
Raizman J, Quinn F, Armbruster D, Adeli K
Clin Chem Lab Med . 2015 Apr; 53(10):e239-43. PMID: 25883205
No abstract available.
6.
Armbruster D, Overcash D, Reyes J
Clin Biochem Rev . 2014 Oct; 35(3):143-53. PMID: 25336760
The era of automation arrived with the introduction of the AutoAnalyzer using continuous flow analysis and the Robot Chemist that automated the traditional manual analytical steps. Successive generations of stand-alone...
7.
Baugher B, Berman M, Dierksen J, Armbruster D, Dasgupta A
J Clin Lab Anal . 2014 Mar; 29(1):1-4. PMID: 24659366
Asian, Siberian, and American ginseng are known to interfere with serum digoxin measurements using fluorescence polarization technology, Digoxin II and Digoxin III assays (Abbott Laboratories, Green oaks, IL) as well...
8.
Levine D, Maine G, Armbruster D, Mussell C, Buchholz C, OConnor G, et al.
Clin Chem . 2011 Oct; 57(12):1739-47. PMID: 21998339
Background: Owing to the lack of an internationally recognized tacrolimus reference material and reference method, current LC-MS and immunoassay test methods used to monitor tacrolimus concentrations in whole blood are...
9.
Armbruster D, Pry T
Clin Biochem Rev . 2008 Oct; 29 Suppl 1:S49-52. PMID: 18852857
* Limit of Blank (LoB), Limit of Detection (LoD), and Limit of Quantitation (LoQ) are terms used to describe the smallest concentration of a measurand that can be reliably measured...
10.
Armbruster D, Alexander D
Clin Chim Acta . 2006 Jun; 373(1-2):37-43. PMID: 16777083
Background: Integrated systems that combine clinical chemistry and immunoassay analyzers are used routinely. Sample to sample carryover is an inherent risk and can cause erroneously high patient test results for...