» Authors » Daniel P Melby

Daniel P Melby

Explore the profile of Daniel P Melby including associated specialties, affiliations and a list of published articles. Areas
Snapshot
Articles 13
Citations 291
Followers 0
Related Specialties
Top 10 Co-Authors
Published In
Affiliations
Soon will be listed here.
Recent Articles
1.
Melby D, Tholakanahalli V, Itah R, Abdelhadi R, Sengupta J, Gornick C, et al.
Heart Rhythm O2 . 2023 Jan; 3(6Part A):665-672. PMID: 36589915
Background: Persistent atrial fibrillation (AF) is a complex arrhythmia, and attaining freedom from AF with ablation has been challenging. Objectives: This study evaluated a novel CARTO software algorithm based on...
2.
Melby D
J Innov Card Rhythm Manag . 2020 Jun; 8(11):2907-2917. PMID: 32477760
Atrial fibrillation (AF) is one of the most common arrhythmias encountered in clinical practice today. Over the last 20 years, the frequency of use of catheter ablation to treat AF...
3.
Natale A, Monir G, Patel A, Fishel R, Marchlinski F, Delaughter M, et al.
J Interv Card Electrophysiol . 2020 May; 61(1):63-69. PMID: 32462550
Purpose: The prospective, multicenter SMART SF trial demonstrated the acute safety and effectiveness of the 56-hole porous tip irrigated contact force (CF) catheter for drug-refractory paroxysmal atrial fibrillation (PAF) ablation...
4.
Melby D, Gornick C, Abdelhadi R, Sengupta J, Pai M, Zakaib J, et al.
J Cardiovasc Electrophysiol . 2019 Jul; 30(10):1860-1867. PMID: 31353679
Background: Ablation of persistent atrial fibrillation (AF) remains challenging. Identification and ablation of localized AF drivers may offer the possibility for improved outcomes. Ripple map is a novel software algorithm...
5.
Reddy V, Pollak S, Lindsay B, McElderry H, Natale A, Kantipudi C, et al.
JACC Clin Electrophysiol . 2018 May; 2(6):691-699. PMID: 29759747
Objectives: This study sought to assess the correlation between catheter and tissue contact force (CF) stability and 12-month clinical success for atrial fibrillation (AF) ablation. Background: The SMART-AF (Thermocool Smarttouch...
6.
Chinitz L, Melby D, Marchlinski F, Delaughter C, Fishel R, Monir G, et al.
Europace . 2017 Oct; 20(FI_3):f392-f400. PMID: 29016769
Aims: THERMOCOOL SMARTTOUCH® SF Catheter is a new contact-force (CF)-sensing catheter with 56-hole porous tip designed for improved cooling and reduced fluid delivery compared with a standard 6-hole open-irrigated catheter....
7.
Lin Y, Melby D, Krishnan B, Adabag S, Tholakanahalli V, Li J
J Interv Card Electrophysiol . 2017 Apr; 49(2):205-209. PMID: 28413855
Purpose: The aim of this study is to investigate the frequency of electrosurgery-related pacemaker malfunction. Methods: A retrospective study was conducted to investigate electrosurgery-related pacemaker malfunction in consecutive patients undergoing...
8.
Natale A, Reddy V, Monir G, Wilber D, Lindsay B, McElderry H, et al.
J Am Coll Cardiol . 2014 Aug; 64(7):647-56. PMID: 25125294
Background: Catheter ablation is important for treatment of paroxysmal atrial fibrillation (PAF). Limited animal and human studies suggest a correlation between electrode-tissue contact and radiofrequency lesion generation. Objectives: The study...
9.
Kallinen L, Hauser R, Tang C, Melby D, Almquist A, Katsiyiannis W, et al.
Heart Rhythm . 2010 May; 7(8):1048-55. PMID: 20493965
Background: The Medtronic Sprint Fidelis high-voltage implantable cardioverter-defibrillator (ICD) lead is prone to fracture. The majority of fractures involve the pace-sense (P/S) conductors and may result in multiple inappropriate shocks....
10.
Katsiyiannis W, Melby D, Matelski J, Ervin V, Laverence K, Gornick C
Am J Cardiol . 2008 Dec; 102(12):1674-6. PMID: 19064022
Radiofrequency ablation for atrial fibrillation (AF) involves complex catheter manipulation resulting in prolonged procedure time and fluoroscopy exposure. Remote magnetic navigation (RMN) represents a novel approach toward improving the ability...