Chandrashekhar M Tambe
Overview
Explore the profile of Chandrashekhar M Tambe including associated specialties, affiliations and a list of published articles.
Author names and details appear as published. Due to indexing inconsistencies, multiple individuals may share a name, and a single author may have variations. MedLuna displays this data as publicly available, without modification or verification
Snapshot
Snapshot
Articles
10
Citations
26
Followers
0
Related Specialties
Related Specialties
Top 10 Co-Authors
Top 10 Co-Authors
Published In
Published In
Affiliations
Affiliations
Soon will be listed here.
Recent Articles
1.
Bindal A, Mahantshetty U, Tambe C, Ghadi Y, Murthy V, Shrivastava S
J Contemp Brachytherapy
. 2016 Jan;
7(6):503-7.
PMID: 26816509
Purpose: Penile cancer, although rare, is one of the common genitourinary cancers in India affecting mostly aged uncircumcised males. For patients presenting with small superficial lesions < 3 cm restricted...
2.
Kinhikar R, Tambe C, Patil K, Mandavkar M, Deshpande D, Gujjalanavar R, et al.
J Med Phys
. 2014 Mar;
39(1):40-3.
PMID: 24600171
The objective of this study was to investigate the dose enhancement to soft tissue due to backscatter radiation near metal interfaces during head and neck radiotherapy. The influence of titanium-mandibular...
3.
Kinhikar R, Sharma S, Upreti R, Tambe C, Deshpande D
J Med Phys
. 2011 Jan;
32(1):29-33.
PMID: 21217916
A new generation telecobalt unit, Theratron Equinox-80, (MDS Nordion, Canada) has been evaluated. It is equipped with a single 60-degree motorized wedge (MW), four universal wedges (UW) for 15°, 30°,...
4.
Kinhikar R, Sharma P, Patkar S, Tambe C, Deshpande D
J Med Phys
. 2010 Dec;
32(2):56-9.
PMID: 21157535
Dynamic multileaf collimator (DMLC) and static multileaf collimator (SMLC), along with three-dimensional treatment planning system (3-D TPS), open the possibility of tissue compensation. A method using electronic tissue compensator (ETC)...
5.
Kinhikar R, Tambe C, Upreti R, Patkar S, Patil K, Deshpande D
Med Dosim
. 2008 Nov;
33(4):286-92.
PMID: 18973856
Anatomic contour irregularity and tissue inhomogeneity in head-and-neck radiotherapy can lead to significant dose inhomogeneity due to the presence of hot and cold spots across the treatment volumes. Missing tissue...
6.
Sharma S, Upreti R, Laskar S, Tambe C, Deshpande D, Shrivastava S, et al.
Radiother Oncol
. 2007 Dec;
86(2):177-81.
PMID: 18082906
Purpose: To estimate the risk of radiation-induced carcinogenesis based on whole-body dose measurement on adolescent patients undergoing intensity-modulated radiotherapy (IMRT). Methods And Materials: Ten adolescent patients with nasopharyngeal cancer were...
7.
Kinhikar R, Patkar S, Tambe C, Deshpande D
J Cancer Res Ther
. 2007 Dec;
3(3):140-2.
PMID: 18079575
Purpose: To estimate the transit dose from motorized wedge (MW) treatment in Equinox-80 telecobalt machine. Materials And Methods: Two plans were generated in Eclipse treatment planning system with universal wedge...
8.
Kinhikar R, Sharma P, Tambe C, Mahantshetty U, Sarin R, Deshpande D, et al.
Phys Med Biol
. 2006 Jul;
51(14):N263-8.
PMID: 16825729
In our earlier study, we experimentally evaluated the characteristics of a newly designed metal oxide semiconductor field effect transistor (MOSFET) OneDose in-vivo dosimetry system for Ir-192 (380 keV) energy and...
9.
Kinhikar R, Sharma P, Tambe C, Deshpande D
Phys Med Biol
. 2006 Feb;
51(5):1261-8.
PMID: 16481692
The purpose of this study was to investigate dosimetry (reproducibility, energy correction, relative response with distance from source, linearity with threshold dose, rate of fading, temperature and angular dependence) of...
10.
Sharma D, Jalali R, Tambe C, Animesh , Deshpande D
Radiother Oncol
. 2004 Mar;
70(1):49-54.
PMID: 15036852
Background And Purpose: The aim of this work was to measure the dose to foetus both in vivo and in vitro during three-dimensional conformal radiation therapy (3DCRT) in a pregnant...