C D Gottlieb
Overview
Explore the profile of C D Gottlieb including associated specialties, affiliations and a list of published articles.
Author names and details appear as published. Due to indexing inconsistencies, multiple individuals may share a name, and a single author may have variations. MedLuna displays this data as publicly available, without modification or verification
Snapshot
Snapshot
Articles
53
Citations
587
Followers
0
Related Specialties
Related Specialties
Top 10 Co-Authors
Top 10 Co-Authors
Published In
Published In
Affiliations
Affiliations
Soon will be listed here.
Recent Articles
1.
Coyne R, Deely M, Gottlieb C, Marchlinski F, Callans D
J Interv Card Electrophysiol
. 2001 Jan;
4(4):635-43.
PMID: 11141211
Introduction: Although recent studies have demonstrated that the endpoint of isthmus conduction block is superior to that of termination and subsequent inability to induce atrial flutter (AFl), the optimal method...
2.
Marchlinski F, Ren J, Schwartzman D, Callans D, Gottlieb C
J Interv Card Electrophysiol
. 2000 Aug;
4(2):415-21.
PMID: 10936007
The crista terminalis is an important anatomic target for ablation of atrial arrhythmias. We determined the accuracy of catheter placement guided by fluoroscopy alone when directed to 24 sites along...
3.
Sarter B, Callans D, Man D, Coyne R, Schwartzman D, Gottlieb C, et al.
Pacing Clin Electrophysiol
. 2000 May;
23(4 Pt 1):516-21.
PMID: 10793444
Isthmus conduction block, demonstrated with the use of multipolar catheter recordings, is considered the preferred endpoint for ablation of type I atrial flutter. This study investigated the feasibility of using...
4.
Marchlinski F, Callans D, Gottlieb C, Zado E
Circulation
. 2000 Mar;
101(11):1288-96.
PMID: 10725289
Background: Conventional activation mapping is difficult without inducible, stable ventricular tachycardia (VT). Methods And Results: We evaluated 16 patients with drug refractory, unimorphic, unmappable VT. Nine patients had ischemic and...
5.
Zado E, Callans D, Gottlieb C, Kutalek S, Wilbur S, Samuels F, et al.
J Am Coll Cardiol
. 2000 Feb;
35(2):458-62.
PMID: 10676694
Objectives: To determine whether catheter ablation is safe and effective in patients over the age of 80. Background: There is a tendency to withhold invasive therapy in the elderly until...
6.
Ren J, Schwartzman D, Callans D, Brode S, Gottlieb C, Marchlinski F
Ultrasound Med Biol
. 1999 Nov;
25(7):1077-86.
PMID: 10574340
A new low-frequency (9 MHz, 9 Fr) catheter-based ultrasound (US) transducer has been designed that allows greater depth of cardiac imaging. To demonstrate the imaging capability and clinical utility, intracardiac...
7.
Callans D, Ren J, Schwartzman D, Gottlieb C, Chaudhry F, Marchlinski F
J Am Coll Cardiol
. 1999 May;
33(6):1667-70.
PMID: 10334440
Objectives: The study explored the potential for tissue swelling and venous occlusion during radiofrequency (RF) catheter ablation procedures using intracardiac echocardiography (ICE). Background: Transient superior vena cava occlusion has been...
8.
Man D, Sarter B, Coyne R, Callans D, Schwartzman D, Gottlieb C, et al.
Pacing Clin Electrophysiol
. 1999 Mar;
22(2):386-9.
PMID: 10087559
Previous studies in patients with antidromic reciprocating tachycardia (ART) have observed a critical anatomic requirement (> 4 cm) between an antegrade bypass tract limb and a retrograde AV nodal limb....
9.
BIGGER Jr J, Whang W, Rottman J, Kleiger R, Gottlieb C, Namerow P, et al.
Circulation
. 1999 Mar;
99(11):1416-21.
PMID: 10086963
Background: The CABG Patch trial compared prophylactic implantable cardiac-defibrillator (ICD) implantation with no antiarrhythmic therapy in coronary bypass surgery patients who had a left ventricular ejection fraction <0.36 and an...
10.
Ren J, Schwartzman D, Callans D, Marchlinski F, Gottlieb C, Chaudhry F
Am J Cardiol
. 1999 Jan;
82(12):1557-60, A8.
PMID: 9874071
Intracardiac echocardiography using a new 9-MHz ultrasound catheter was performed in 30 patients undergoing percutaneous catheter mapping and radiofrequency ablation of a tachyarrhythmia, because the imaging capabilities with this intracardiac...