Alberto Villarrubia
Overview
Explore the profile of Alberto Villarrubia including associated specialties, affiliations and a list of published articles.
Author names and details appear as published. Due to indexing inconsistencies, multiple individuals may share a name, and a single author may have variations. MedLuna displays this data as publicly available, without modification or verification
Snapshot
Snapshot
Articles
19
Citations
51
Followers
0
Related Specialties
Related Specialties
Top 10 Co-Authors
Top 10 Co-Authors
Published In
Published In
Affiliations
Affiliations
Soon will be listed here.
Recent Articles
1.
Cano-Ortiz A, Sanchez-Ventosa A, Gonzalez M, Gonzalez-Cruces T, Perez M, Ramos J, et al.
Graefes Arch Clin Exp Ophthalmol
. 2025 Mar;
PMID: 40082269
Purpose: To compare the results in terms of visual acuity and complication rates between eyes undergoing Descemet's membrane endothelial keratoplasty (DMEK) with the help or not of intraoperative optical coherence...
2.
Gonzalez-Cruces T, Aguilar-Salazar F, Tort J, Sanchez-Ventosa A, Villarrubia A, Mateu J, et al.
J Cataract Refract Surg
. 2025 Jan;
PMID: 39885651
Purpose: The main objective was to develop a prediction model based on machine learning to calculate the postoperative vault as well as the ideal implantable collamer lens (ICL) size, considering...
3.
Cano-Ortiz A, Sanchez-Ventosa A, Gonzalez-Cruces T, Gonzalez M, Perez M, Diaz-Ramos J, et al.
J Clin Med
. 2024 Dec;
13(23).
PMID: 39685864
This study aimed to evaluate the initial clinical outcomes of and patient satisfaction with the newly introduced extended monofocal Evolux™ intraocular lens following cataract surgery. A retrospective study was conducted,...
4.
Sanchez-Ventosa A, Cano-Ortiz A, Gonzalez Cruces T, Gonzalez M, Membrillo A, Villarrubia A
J Cataract Refract Surg
. 2024 Jul;
50(8):816-821.
PMID: 39083408
Purpose: To evaluate the clinical outcomes of the Visian implantable collamer lens (ICL) in eyes with ≥17 years of follow-up. Setting: Single-center. Design: Retrospective observational study. Methods: 70 eyes from...
5.
Gonzalez-Cruces T, Sanchez-Ventosa A, Villarrubia A, Sanchez-Gonzalez J, Cano-Ortiz A
J Cataract Refract Surg
. 2023 Aug;
49(12):1249-1257.
PMID: 37651314
Purpose: To compare 2 techniques to correct low astigmatism during implantable collamer lens (ICL) surgery: astigmatic opposite clear corneal incisions (OCCIs) and toric ICL (T-ICL). Setting: Arruzafa Ophthalmological Hospital, Cordoba,...
6.
Villarrubia A, Sanchez Ventosa A, Cubero Parra J, Spinola Moreno C, Laborda Onate J, Miranda E, et al.
Graefes Arch Clin Exp Ophthalmol
. 2022 Dec;
261(5):1331-1338.
PMID: 36480049
Purpose: This study is to describe the clinical outcome of penetrating keratoplasty combined with implantation of a novel intraocular lens with an artificial iris, aided by continuous vitreous chamber infusion,...
7.
Gonzalez-Cruces T, Villarrubia A, Sanchez Ventosa A, Miranda E, Castillo Eslava R, Gomera Martinez A, et al.
J Refract Surg
. 2022 Nov;
38(11):698-707.
PMID: 36367259
Purpose: To compare two aspheric ablation profiles in myopic refractive surgery using different asphericity targets. Methods: Patients underwent laser in situ keratomileusis (LASIK) with the WaveLight EX500 laser platform (Alcon,...
8.
Gonzalez-Cruces T, Cano-Ortiz A, Villarrubia A, Sanchez-Gonzalez M, Sanchez-Gonzalez J
Eur J Ophthalmol
. 2022 Aug;
:11206721221121439.
PMID: 36036354
Purpose: Incision architecture can play an important role in corneal astigmatism management through peripheral corneal relaxing incisions. The aim of this study was to compare the incision architecture of single-plane...
9.
Dick H, Ang R, Corbett D, Hoffmann P, Tetz M, Villarrubia A, et al.
J Cataract Refract Surg
. 2022 May;
48(11):1270-1276.
PMID: 35545816
Purpose: To compare the clinical performance of the TECNIS Synergy multifocal (model ZFR00V) intraocular lens (IOL) with that of the AcrySof PanOptix Trifocal (model TFNT00) IOL in patients undergoing bilateral...
10.
Sanchez-Ventosa A, Cano-Ortiz A, Morales P, Gonzalez-Cruces T, Diaz Mesa V, Villarrubia A
Int Ophthalmol
. 2021 Oct;
42(3):989-995.
PMID: 34643838
Purpose: To create a nomogram including the translational speed of the microkeratome blade, microkeratome head size and precut tissue thickness to predict the postcut thickness for Descemet stripping automated endothelial...