» Authors » A Mahendrasingam

A Mahendrasingam

Explore the profile of A Mahendrasingam including associated specialties, affiliations and a list of published articles. Areas
Snapshot
Articles 14
Citations 47
Followers 0
Related Specialties
Top 10 Co-Authors
Published In
Affiliations
Soon will be listed here.
Recent Articles
1.
Martin C, Eeckhaut G, Mahendrasingam A, Blundell D, Fuller W, Oldman R, et al.
J Synchrotron Radiat . 2006 Apr; 7(Pt 4):245-50. PMID: 16609202
A microdeformation stage based on a piezoelectric crystal actuator capable of measuring the force applied to micrometre-sized polymeric samples is described. Laboratory force/strain measurements on a single strut of an...
2.
Martin C, Mahendrasingam A, Fuller W, Harvie J, Blundell D, Whitehead J, et al.
J Synchrotron Radiat . 1997 Jul; 4(Pt 4):223-7. PMID: 16699234
The microfocus X-ray beamline at the European Synchrotron Radiation Facility has been used to investigate the variation in molecular orientation and crystallinity in the wall of a container fabricated from...
3.
Hughes D, Mahendrasingam A, Heeley E, Oatway W, Martin C, Towns-Andrews E, et al.
J Synchrotron Radiat . 1996 Mar; 3(Pt 2):84-90. PMID: 16702663
A system has been developed which represents a significant advance in the quality and extent of small- and wide-angle X-ray scattering data (SAXS and WAXS) that can be recorded simultaneously...
4.
Forsyth V, Langan P, Whalley M, Mahendrasingam A, Wilson C, Giesen U, et al.
Basic Life Sci . 1996 Jan; 64:359-67. PMID: 9031520
The diffractometer SXD at the Rutherford Appleton Laboratory ISIS pulsed neutron source has been used to record high resolution time-of-flight Laue fiber diffraction data from DNA. These experiments, which are...
5.
Fuller W, Forsyth V, Mahendrasingam A, Langan P, Pigram W, Mason S, et al.
Basic Life Sci . 1996 Jan; 64:345-58. PMID: 9031519
The development of neutron high angle fiber diffraction to investigate the location of water around the deoxyribonucleic acid (DNA) double-helix is described. The power of the technique is illustrated by...
6.
Mahendrasingam A, Martin C, Fuller W, Blundell D, Mackerron D, Rule R, et al.
J Synchrotron Radiat . 1995 Nov; 2(Pt 6):308-12. PMID: 16714835
The microfocus X-ray beamline at the European Synchrotron Radiation Facility has been used to investigate the variation in molecular orientation and crystallinity in spherulites of the organic polymer poly-3-hydroxybutyrate (PHB)....
7.
Hubbard S, Greenall R, Shrive A, Forsyth V, Mahendrasingam A
Int J Biol Macromol . 1994 Aug; 16(4):195-205. PMID: 7848967
In this paper, the side-by-side model of DNA proposed by Premilat and Albiser is investigated. The axial repeat of the model is equal to the c-axis repeat in the observed...
8.
Langan P, Forsyth V, Mahendrasingam A, Pigram W, Mason S, Fuller W
J Biomol Struct Dyn . 1992 Dec; 10(3):489-503. PMID: 1492921
A high angle neutron fibre diffraction study of the distribution of water around the A-form of DNA has been performed using the diffractometer D19 at the Institut Laue-Langevin, Grenoble. These...
9.
Forsyth V, Mahendrasingam A, Pigram W, Greenall R, Bellamy K, Fuller W, et al.
Int J Biol Macromol . 1989 Aug; 11(4):236-40. PMID: 2489087
Interactions with water are crucial to the conformation assumed by the DNA double helix. The location of water around the D conformation has been investigated in a neutron fibre diffraction...
10.
Mahendrasingam A, Forsyth V, Hussain R, Greenall R, Pigram W, Fuller W
Science . 1986 Jul; 233(4760):195-7. PMID: 3726529
Because of the relation between topology and function, there has been much interest in the structural transitions of the various conformations of DNA polymers. The x-ray fiber diffraction analysis system...