A Duquennoy
Overview
Explore the profile of A Duquennoy including associated specialties, affiliations and a list of published articles.
Author names and details appear as published. Due to indexing inconsistencies, multiple individuals may share a name, and a single author may have variations. MedLuna displays this data as publicly available, without modification or verification
Snapshot
Snapshot
Articles
85
Citations
344
Followers
0
Related Specialties
Related Specialties
Top 10 Co-Authors
Top 10 Co-Authors
Published In
Published In
Affiliations
Affiliations
Soon will be listed here.
Recent Articles
1.
Mesnil P, Vasseur L, Wavreille G, Fontaine C, Duquennoy A, Migaud H
Orthop Traumatol Surg Res
. 2014 Apr;
100(4):369-73.
PMID: 24768433
Introduction: Although Charnley-Kerboull metal-on-polyethylene 22.2mm cemented total hip arthroplasty (THA) is considered to be the gold standard in France, results with this prosthesis are conflicting, in particular in relation to...
2.
Hildebrand H, Laffargue P, Decoulx J, Duquennoy A, Mestdagh H
Int J Risk Saf Med
. 2013 Mar;
8(1):125-34.
PMID: 23511895
Metal ion release was assessed in 31 patients with loosening of total hip replacements (THR). Three types of alloys were used for these prostheses: stainless steel (9/31), Ni-Cr-Mo (5/31) and...
3.
Trichard T, Remy F, Girard J, Soenen M, Duquennoy A, Migaud H
Rev Chir Orthop Reparatrice Appar Mot
. 2006 Nov;
92(7):701-7.
PMID: 17124454
Purpose Of The Study: Theoretically, long-term functional and radiographic degradation is predictable after ankle fusion, but sound evidence from the consecutive analysis of the same cohort is lacking. The purpose...
4.
Ala Eddine T, Remy F, Chantelot C, Giraud F, Migaud H, Duquennoy A
Rev Chir Orthop Reparatrice Appar Mot
. 2002 Feb;
87(8):815-9.
PMID: 11845085
Purpose Of The Study: Impingement of the iliopsoas muscle due to a protruding acetabular component is an uncommon cause of pain after total hip arthroplasty. Diagnostic signs may be misleading...
5.
Eddine T, Migaud H, Chantelot C, Cotten A, Fontaine C, Duquennoy A
Surg Radiol Anat
. 2001 Jul;
23(2):105-10.
PMID: 11462858
The position of the acetabular implant plays a dominant role in the displacement of a total hip prosthesis. CT allows precise measurement of the position of the cup, but the...
6.
Chapnikoff D, Besson A, Chantelot C, Fontaine C, Migaud H, Duquennoy A
Rev Chir Orthop Reparatrice Appar Mot
. 2000 Nov;
86(6):558-65.
PMID: 11060429
Purpose Of The Study: There are few reports onlong-term outcome after Bankart procedure. The purpose of this study was to determine the rate of recurrent dislocation, the clinical results and...
7.
Chantelot C, Fontaine C, Diop A, Migaud H, Lavaste F, Duquennoy A
Ann Chir Main Memb Super
. 2000 Aug;
17(1):68-77.
PMID: 10941387
We used an electromagnetic goniometer to study the angular and translations displacements between the humerus and the 2 bones of the forearm. The electromagnetic gionometer allows acquisition of the coordinates...
8.
Chantelot C, Fontaine C, Jardin C, Migaud H, Le Coustumer F, Duquennoy A
Chir Main
. 2000 Jun;
17(3):236-44.
PMID: 10855291
Between 1984 and 1995, 39 patients underwent wrist synovectomy-stabilisation. Among these patients, 5 had died and 2 could not rectum for review. These 7 patients were excluded from the study....
9.
Chantelot C, Fontaine C, Migaud H, Remy F, Chapnikoff D, Duquennoy A
Rev Chir Orthop Reparatrice Appar Mot
. 2000 Jan;
85(8):823-7.
PMID: 10637883
Introduction: The goal of the study was to determine the results of elbow arthrolysis for post-traumatic stiffness, and to identify factors governing the result of that procedure. Patients And Methods:...
10.
Besson A, Brazier J, Chantelot C, Migaud H, Gougeon F, Duquennoy A
Rev Chir Orthop Reparatrice Appar Mot
. 2000 Jan;
85(8):797-802.
PMID: 10637880
Purpose Of The Study: The preservation of the posterior cruciate ligament (PCL) was introduced in total knee arthroplasty to improve the quadriceps efficiency and the range of flexion in stairs....