» Articles » PMID: 9882773

Assessment of Regional Wall Motion Abnormalities with Real-time 3-dimensional Echocardiography

Overview
Specialty Radiology
Date 1999 Jan 12
PMID 9882773
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

Accurate characterization of regional wall motion abnormalities requires a thorough evaluation of the entire left ventricle (LV). Although 2-dimensional echocardiography is frequently used for this purpose, the inability of tomographic techniques to record the complete endocardial surface is a limitation. Three-dimensional echocardiography, with real-time volumetric imaging, has the potential to overcome this limitation by capturing the entire volume of the LV and displaying it in a cineloop mode. The purpose of this study was to assess the feasibility of using real-time 3-dimensional (RT3D) echocardiography to detect regional wall motion abnormalities in patients with abnormal LV function and to develop a scheme for the systematic evaluation of wall motion by using the 3-dimensional data set. Twenty-six patients with high-quality 2-dimensional echo images and at least 1 regional wall motion abnormality were examined with RT3D echocardiography. For 2-dimensional echocardiography, wall motion was analyzed with a 16-segment model and graded on a 4-point scale from normal (1) to dyskinetic (4), from which a wall motion score index was calculated. Individual segments were then grouped into regions (anterior, inferoposterior, lateral, and apical) and the number of regional wall motion abnormalities was determined. The RT3D echocardiogram was recorded as a volumetric, pyramid-shaped data set that contained the entire LV. Digital images, consisting of a single cardiac cycle cineloop, were analyzed off-line with a computerized display of the apical projection. Two intersecting orthogonal apical projections were simultaneously displayed in cineloop mode, each independently tilted to optimize orientation and endocardial definition. The 2 planes were then slowly rotated about the major axis to visualize the entire LV endocardium. Wall motion was then graded in 6 equally spaced views, separated by 30 degrees, yielding 36 segments per patient. A higher percentage of segments were visualized with 2-dimensional versus RT3D echocardiography (97% vs 83%, respectively, P <.001). With the use of the 2-dimensional echocardiographic results as the standard, RT3D echocardiography detected 55 (96%) of 57 regional wall motion abnormalities. Analysis of the RT3D echocardiograms resulted in 3 false-negative and 5 false-positive findings. The total number of regional wall motion abnormalities was correctly classified by RT3D echocardiography in 19 (73%) of 26 patients. RT3D echocardiography detected 11 of 13 anterior, 19 of 20 inferoposterior, 9 of 9 lateral, and 15 of 15 apical wall motion abnormalities. An excellent correlation was found between the 2 techniques for assessment of the regional wall motion score index (r = 0.89, P <.001). This initial clinical study demonstrates the feasibility and potential advantages of RT3D echocardiography for the assessment of regional LV function. Compared with 2-dimensional echocardiography, this new method permits recording of the entire LV in a single beat, allowing the extent and location of the regional wall motion abnormalities to be determined.

Citing Articles

Relationship between Preoperative Echocardiographic Parameters and the Incidence of Postoperative Complications in Patients Undergoing Clipping of Unruptured Intracranial Aneurysms: A Retrospective Cohort Study.

Park Y, Lee S, Sim J, Moon B, Kim K, Ha S Medicina (Kaunas). 2023; 59(10).

PMID: 37893414 PMC: 10608654. DOI: 10.3390/medicina59101697.


Assessment of left ventricular regional wall motion abnormalities using regional time-volume curves obtained by real time three-dimensional echocardiography.

Youssef G, Saad Z, Ammar W, Sharaf Y Egypt Heart J. 2018; 70(3):189-194.

PMID: 30190645 PMC: 6123227. DOI: 10.1016/j.ehj.2018.02.002.


Three-dimensional echocardiography in various types of heart disease: a comparison study of magnetic resonance imaging and 64-slice computed tomography in a real-world population.

Squeri A, Censi S, Reverberi C, Gaibazzi N, Baldelli M, Binno S J Echocardiogr. 2016; 15(1):18-26.

PMID: 27589871 DOI: 10.1007/s12574-016-0315-3.


Efficacy of a device to narrow the coronary sinus in refractory angina.

Verheye S, Jolicoeur E, Behan M, Pettersson T, Sainsbury P, Hill J N Engl J Med. 2015; 372(6):519-27.

PMID: 25651246 PMC: 6647842. DOI: 10.1056/NEJMoa1402556.


Initial experience using contrast enhanced real-time three-dimensional exercise stress echocardiography in a low-risk population.

Stergiopoulos K, Bahrainy S, Buzzanca L, Blizzard B, Gamboa J, Kort S Heart Int. 2011; 5(1):e8.

PMID: 21977293 PMC: 3184705. DOI: 10.4081/hi.2010.e8.