» Articles » PMID: 9867327

In Vivo Crushing of an Aortic Stent Enables Endovascular Repair of a Large Infrarenal Aortic Pseudoaneurysm

Overview
Journal J Endovasc Surg
Date 1998 Dec 29
PMID 9867327
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To report an unusual approach to endovascular exclusion of a large aortic pseudoaneurysm.

Methods And Results: A 63-year-old male had an unsuccessful endovascular repair of an aortic anastomotic pseudoaneurysm that left an expanded, uncovered Palmaz stent lying obliquely within the aorta. After nearly 3 years, the pseudoaneurysm enlarged to 7 cm, and the patient became symptomatic. Repair of the pseudoaneurysm was accomplished by crushing the indwelling stent to allow placement of a stent-graft.

Conclusions: Malpositioned stents that are hindering an endoluminal procedure may be crushed against the arterial wall in vivo to facilitate passage of endovascular instruments or devices.

Citing Articles

Massive hematuria due to an autogenous saphenous vein graft and urinary bladder fistula in an extra-anatomic iliofemoral bypass: a case report.

Jaha L, Ismaili-Jaha V, Ademi B, Veselaj F, Kryeziu D, Gjikolli B J Med Case Rep. 2019; 13(1):359.

PMID: 31812163 PMC: 6899332. DOI: 10.1186/s13256-019-2300-8.


How I do it: thrombosed arteriovenous graft resulting from a crushed stent in a nonambulatory hemodialysis patient.

Wasse H Semin Dial. 2008; 21(2):178-9.

PMID: 18226009 PMC: 2728771. DOI: 10.1111/j.1525-139X.2007.00398.x.