Human Magnetic Resonance Imaging at 8 T

Overview
Journal NMR Biomed
Publisher Wiley
Date 1998 Nov 5
PMID 9802467
Citations 25
Authors
Affiliations
Soon will be listed here.
Abstract

In this work, we present the first human magnetic resonance image (MRI) obtained at ultrahigh field strengths (8 T). We demonstrate that clinical imaging will be possible at 8 T and that reasonable quality head images can be obtained at this field strength. Most importantly, we emphasize that the power required to excite the spins at 8 T is much lower than had previously been predicted by the nuclear magnetic resonance theory. A 90 degree pulse in the head at 8 T requires only approximately 0.085 J of energy (90 W for a 2-lobe 4 ms sinc pulse). Based on measurements at 4 T, 1-2 J of energy should have been utilized to achieve a 90 degree excitation at 8 T. The fact that the energy required for spin excitation at 8 T is much lower than predicted by the NMR theory, will be extremely important to the viability of ultrahigh field imaging, since concerns related to power absorption and specific absorption rate (SAR) violations at ultrahigh field are alleviated. As such, it will be possible to utilize RF intensive pulse sequences and adiabatic spin excitation at 8 T without significant risk to the subject.

Citing Articles

High-Density MRI RF Arrays Using Mixed Dipole Antennas and Microstrip Transmission Line Resonators.

Lu M, Sengupta S, Gore J, Grissom W, Yan X IEEE Trans Biomed Eng. 2022; 69(10):3243-3252.

PMID: 35404807 PMC: 9587496. DOI: 10.1109/TBME.2022.3166279.


MRI with ultrahigh field strength and high-performance gradients: challenges and opportunities for clinical neuroimaging at 7 T and beyond.

Vachha B, Huang S Eur Radiol Exp. 2021; 5(1):35.

PMID: 34435246 PMC: 8387544. DOI: 10.1186/s41747-021-00216-2.


Magnetic Resonance Imaging Correlates of White Matter Gliosis and Injury in Preterm Fetal Sheep Exposed to Progressive Systemic Inflammation.

Galinsky R, van de Looij Y, Mitchell N, Dean J, Dhillon S, Yamaguchi K Int J Mol Sci. 2020; 21(23).

PMID: 33255257 PMC: 7727662. DOI: 10.3390/ijms21238891.


Introduction of Ultra-High-Field MR Imaging in Infants: Preparations and Feasibility.

Annink K, van der Aa N, Dudink J, Alderliesten T, Groenendaal F, Lequin M AJNR Am J Neuroradiol. 2020; 41(8):1532-1537.

PMID: 32732273 PMC: 7658868. DOI: 10.3174/ajnr.A6702.


Computational and experimental evaluation of the Tic-Tac-Toe RF coil for 7 Tesla MRI.

Krishnamurthy N, Santini T, Wood S, Kim J, Zhao T, Aizenstein H PLoS One. 2019; 14(1):e0209663.

PMID: 30629618 PMC: 6328242. DOI: 10.1371/journal.pone.0209663.