Noninvasive Measurement of Pulsatile Intracranial Pressure Using Ultrasound

Overview
Specialty Neurosurgery
Date 1998 Oct 21
PMID 9779147
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

The present study was designed to validate our noninvasive ultrasonic technique (pulse phase locked loop: PPLL) for measuring intracranial pressure (ICP) waveforms. The technique is based upon detecting skull movements which are known to occur in conjunction with altered intracranial pressure. In bench model studies, PPLL output was highly correlated with changes in the distance between a transducer and a reflecting target (R2 = 0.977). In cadaver studies, transcranial distance was measured while pulsations of ICP (amplitudes of zero to 10 mmHg) were generated by rhythmic injections of saline. Frequency analyses (fast Fourier transformation) clearly demonstrate the correspondence between the PPLL output and ICP pulse cycles. Although theoretically there is a slight possibility that changes in the PPLL output are caused by changes in the ultrasonic velocity of brain tissue, the decreased amplitudes of the PPLL output as the external compression of the head was increased indicates that the PPLL output represents substantial skull movement associated with altered ICP. In conclusion, the ultrasound device has sufficient sensitivity to detect transcranial pulsations which occur in association with the cardiac cycle. Our technique makes it possible to analyze ICP waveforms noninvasively and will be helpful for understanding intracranial compliance and cerebrovascular circulation.

Citing Articles

Non-Invasive Intracranial Pressure Monitoring.

Muller S, Henkes E, Gounis M, Felber S, Ganslandt O, Henkes H J Clin Med. 2023; 12(6).

PMID: 36983213 PMC: 10051320. DOI: 10.3390/jcm12062209.


A mathematical model for predicting intracranial pressure based on noninvasively acquired PC-MRI parameters in communicating hydrocephalus.

Long J, Sun D, Zhou X, Huang X, Hu J, Xia J J Clin Monit Comput. 2020; 35(6):1325-1332.

PMID: 33001400 PMC: 7528454. DOI: 10.1007/s10877-020-00598-5.


Prospective Study on Noninvasive Assessment of Intracranial Pressure in Traumatic Brain-Injured Patients: Comparison of Four Methods.

Cardim D, Robba C, Donnelly J, Bohdanowicz M, Schmidt B, Damian M J Neurotrauma. 2015; 33(8):792-802.

PMID: 26414916 PMC: 4841086. DOI: 10.1089/neu.2015.4134.


Non-invasive detection of intracranial hypertension using a simplified intracranial hemo- and hydro-dynamics model.

Lee K, Park C, Oh J, Lee B Biomed Eng Online. 2015; 14:51.

PMID: 26024843 PMC: 4449568. DOI: 10.1186/s12938-015-0051-3.


Noninvasive Measurements of Pressure for Detecting Compartment Syndromes.

Lee S, Padilla M, Lynch J, Hargens A J Orthop Rheumatol. 2014; 1(1):5.

PMID: 25328908 PMC: 4197938.