Performance of Calibration Standards for Antigen Quantitation with Flow Cytometry

Overview
Journal Cytometry
Specialty Cell Biology
Date 1998 Oct 17
PMID 9773879
Citations 14
Authors
Affiliations
Soon will be listed here.
Abstract

In the frame of the activities initiated by the Task Force for Antigen Quantitation of the European Working Group on Clinical Cell Analysis (EWGCCA), an experiment was conducted to evaluate microbead standards used for quantitative flow cytometry (QFCM). An unified window of analysis (UWA) was established on three different instruments (EPICS XL [Coulter Corporation, Miami, FL], FACScan and FACS Calibur [Becton Dickinson, San Jose, CA]) with QC3 microbeads (FCSC, PR). By using this defined fluorescence intensity scale, the performance of several monoclonal antibodies directed to CD3, CD4, and CD8 (conjugated and unconjugated), from three manufacturers (BDIS, Coulter [Immunotech], and DAKO) was tested. In addition, the QIFI system (DAKO) and QuantiBRITE (BDIS), and a method of relative fluorescence intensity (RFI, method of Giorgi), were compared. mAbs reacting with three more antigens, CD16, CD19, and CD38 were tested on the FACScan instrument. Quantitation was carried out using a single batch of cryopreserved peripheral blood leukocytes, and all tests were performed as single color analyses. Significant correlations were observed between the antibody-binding capacity (ABC) values of the same CD antigen measured with various calibrators and with antibodies differing in respect to vendor, labeling and possible epitope recognition. Despite the significant correlations, the ABC values of most monoclonal antibodies differed by 20-40% when determined by the different fluorochrome conjugates and different calibrators. The results of this study indicate that, at the present stage of QFCM consistent ABC values may be attained between laboratories provided that a specific calibration system is used including specific calibrators, reagents, and protocols.

Citing Articles

Efficiency scale for scattering luminescent particles linked to fundamental and measurable spectroscopic properties.

Wurth C, Behnke T, Gienger J, Resch-Genger U Sci Rep. 2023; 13(1):6254.

PMID: 37069220 PMC: 10110600. DOI: 10.1038/s41598-023-32933-6.


Myeloid checkpoint blockade improves killing of T-acute lymphoblastic leukemia cells by an IgA2 variant of daratumumab.

Baumann N, Arndt C, Petersen J, Lustig M, Rosner T, Klausz K Front Immunol. 2022; 13:949140.

PMID: 36052078 PMC: 9427194. DOI: 10.3389/fimmu.2022.949140.


The Development of Fluorescence Intensity Standards.

Gaigalas A, Li L, Henderson O, Vogt R, Barr J, Marti G J Res Natl Inst Stand Technol. 2016; 106(2):381-9.

PMID: 27500028 PMC: 4862808. DOI: 10.6028/jres.106.015.


Engineered hapten-binding antibody derivatives for modulation of pharmacokinetic properties of small molecules and targeted payload delivery.

Dengl S, Sustmann C, Brinkmann U Immunol Rev. 2016; 270(1):165-77.

PMID: 26864111 PMC: 4755198. DOI: 10.1111/imr.12386.


DNA-directed assembly of antibody-fluorophore conjugates for quantitative multiparametric flow cytometry.

Flor A, Williams J, Blaine K, Duggan R, Sperling A, Schwartz D Chembiochem. 2013; 15(2):267-75.

PMID: 24375983 PMC: 3925401. DOI: 10.1002/cbic.201300464.