» Articles » PMID: 9704700

Treatment of Long Dissections by Use of a Single Long or Multiple Short Stents: Clinical and Angiographic Follow-up

Overview
Journal Am Heart J
Date 1998 Aug 15
PMID 9704700
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Recently, long (> or =20 mm) coronary stents were introduced for clinical use. They are intended as an alternative to multiple conventional stents to treat extensive dissections or suboptimal results of long lesions after balloon angioplasty.

Methods: In a total of 113 such consecutive vessels in 107 patients, the flexible Freedom stent was implanted. In 60 of these vessels, because of anatomic constraints, multiple overlapping short (16 mm) stents were implanted. The other 53 vessels were treated with a single long (> or =20 mm) stent.

Results: In the single stent group there were four implantation failures (8%) successfully managed by crossover to multiple overlapping short stents. During early follow-up, in-stent thrombosis was not observed, but three patients with a single long stent and two patients with multiple overlapping stents suffered myocardial infarction as a result of long lasting myocardial ischemia during a difficult angioplasty procedure. At 6-month follow-up, > or =50% restenosis was measured in 29% and 35% of the patients with a single long stent and in those with multiple overlapping stents, respectively (not significant).

Conclusions: Compared with the alternative treatment modality (i.e., implantation of multiple short stents), no difference between in-hospital and 6-month outcome was observed. However, implantation of a single long stent, when technically feasible, reduces catheterization time, dye volume for the patient, and radiation exposure for both patient and operator during these embarrassing angioplasty procedures.

Citing Articles

Ultrathin Strut Biodegradable Polymer-Coated Sirolimus-Eluting Coronary Stents: Patient-Level Pooled Analysis From Two Indian Registries.

Pothineni R, Ajmera P, Chawla K, Mantravadi S, Pathak A, Inamdar M Cureus. 2023; 15(7):e41743.

PMID: 37575772 PMC: 10415628. DOI: 10.7759/cureus.41743.


Single Long Stents versus Overlapping Multiple Stents in the Management of Very Long Coronary Lesions: Comparisons of Procedures and Clinical Outcomes.

Amirzadegan A, Hasanabadi M, Saadatagah S, Afarideh M, Omidi N, Aghajani H J Tehran Heart Cent. 2020; 14(3):94-102.

PMID: 31998385 PMC: 6981347.


Successful Treatment of Symptomatic Intracranial Carotid Artery Stenosis Using a 24-mm Long Bare Metal Coronary Stent.

Rehman A, Turner R, Lucke-Wold B, Boo S World Neurosurg. 2017; 102:693.e15-693.e19.

PMID: 28416412 PMC: 5500919. DOI: 10.1016/j.wneu.2017.04.018.


Outcomes of stenting with overlapping drug-eluting stents versus overlapping drug-eluting and bare-metal stents for the treatment of diffuse coronary lesions.

Kassaian S, Salarifar M, Raissi Dehkordi M, Alidoosti M, Nematipour E, Poorhosseini H Cardiovasc J Afr. 2010; 21(6):311-5.

PMID: 21135978 PMC: 3736383. DOI: 10.5830/cvja-2010-004.