Objective: The purpose of the study was to assess the accuracy of fetal biometry in the midtrimester of pregnancy in the assignment of fetal age.

Study Design: A total of 152 singleton, 67 twin, and 19 triplet gestations resulting from in vitro fertilization with ultrasonographic fetal biometry from 14 to 22 weeks made up the study population. A gestational age prediction equation was derived from singletons with the use of stepwise linear regression. This equation was compared with 38 previously published equations and then applied to the twin and triplet populations.

Results: Head circumference was the best predictor of gestational age (random error [SD] 3.77 days). Addition of abdominal circumference and femur length to head circumference improved the accuracy of the dating equation (random error 3.35 days). Most dating formulas had systematic errors of <1 week. The systematic error was -0.32 day for averaging the singleton-based predictions for twins and -1.26 days for triplets.

Conclusions: Gestational age assessment with the use of fetal biometry from 14 to 22 weeks is accurate for singleton, twin, and triplet gestations.

Citing Articles

The sFlt-1/PlGF Ratio at 12, 24, and 32 Weeks Gestation in Twin Pregnancies as a Predictor of Placental Dysfunction.

Satorres-Perez E, Martinez-Varea A, Novillo-Del Alamo B, Morales-Rosello J, Diago-Almela V J Clin Med. 2024; 13(6).

PMID: 38542007 PMC: 10971022. DOI: 10.3390/jcm13061784.


Risk of stillbirth in singleton fetuses with advancing gestational age at term: A 10-year experience of late third trimester prenatal screenings of 50,000 deliveries in a referral center in northern Italy.

DAmbrosi F, Ruggiero M, Cesano N, Di Maso M, Cetera G, Tassis B PLoS One. 2023; 18(2):e0277262.

PMID: 36812250 PMC: 9946230. DOI: 10.1371/journal.pone.0277262.


Second and third trimester estimation of gestational age using ultrasound or maternal symphysis-fundal height measurements: A systematic review.

Self A, Daher L, Schlussel M, Roberts N, Ioannou C, Papageorghiou A BJOG. 2022; 129(9):1447-1458.

PMID: 35157348 PMC: 9545821. DOI: 10.1111/1471-0528.17123.


Gestational age data completeness, quality and validity in population-based surveys: EN-INDEPTH study.

Haider M, Mahmud K, Blencowe H, Ahmed T, Akuze J, Cousens S Popul Health Metr. 2021; 19(Suppl 1):16.

PMID: 33557866 PMC: 7869446. DOI: 10.1186/s12963-020-00230-3.


Fetal growth standards for Somali population.

Mustafa H, Tessier K, Reagan L, Luo X, Contag S J Matern Fetal Neonatal Med. 2019; 34(15):2440-2453.

PMID: 31544565 PMC: 7085970. DOI: 10.1080/14767058.2019.1667327.