» Articles » PMID: 9554631

Lung Deposition of Fenoterol and Flunisolide Delivered Using a Novel Device for Inhaled Medicines: Comparison of RESPIMAT with Conventional Metered-dose Inhalers with and Without Spacer Devices

Overview
Journal Chest
Publisher Elsevier
Specialty Pulmonary Medicine
Date 1998 Apr 29
PMID 9554631
Citations 37
Authors
Affiliations
Soon will be listed here.
Abstract

Study Objectives: To compare lung deposition of fenoterol or flunisolide administered from a novel, multidose inhalation device delivering liquid droplets (RESPIMAT; Boehringer Ingelheim Ltd; Bracknell, UK) or from conventional metered-dose inhalers (MDIs) with and without spacers.

Design: Two randomized, three-way crossover studies.

Setting: Clinical research laboratory.

Participants: Healthy, nonsmoking volunteers.

Interventions: In one study, radiolabeled aerosols of fenoterol from the RESPIMAT device and from a conventional MDI with or without an Aerochamber spacer (Trudell Medical; London, Ontario Canada). In the second study, radiolabeled aerosols of flunisolide from a RESPIMAT device, from a RESPIMAT device modified by inclusion of a baffle/impactor in the mouthpiece, and from a conventional MDI with an Inhacort spacer (Boehringer Ingelheim; Ingelheim, Germany).

Measurements And Results: Assessment of the deposition of fenoterol or flunisolide in the lung and oropharynx using gamma scintigraphy. Safety was assessed based on reported adverse effects and spirometry (FEV1, FVC, and peak expiratory flow rate) to detect any paradoxical bronchoconstriction. The RESPIMAT device delivered significantly more fenoterol to the lungs than either an MDI alone or an MDI with Aerochamber (39.2% vs 11.0% and 9.9% of metered dose, respectively; p<0.01). Oropharyngeal deposition of fenoterol from the new device was lower than that from the MDI (37.1% vs 71.7%, respectively; p<0.01). The RESPIMAT device deposited significantly more flunisolide in the lungs compared with MDI plus spacer (44.6% vs 26.4%, respectively; p<0.01), while resulting in similar oropharyngeal deposition (26.2% vs 31.2%, respectively). Introduction of a baffle into the RESPIMAT system reduced lung deposition of flunisolide to 29.5%, and oropharyngeal deposition to 7.8% (p<0.01).

Conclusion: The RESPIMAT device may prove to be an effective alternative to MDIs for the administration of inhaled bronchodilators and corticosteroids. The high lung deposition and low oropharyngeal deposition may lead to improved efficacy and tolerability of inhaled medications, especially corticosteroids.

Citing Articles

Aerosol Plumes of Inhalers Used in COPD.

Wachtel H, Emerson-Stadler R, Langguth P, Hohlfeld J, Ohar J Pulm Ther. 2024; 10(1):109-122.

PMID: 38194194 PMC: 10881950. DOI: 10.1007/s41030-023-00249-5.


Pulmonary Delivery of Favipiravir in Rats Reaches High Local Concentrations without Causing Oxidative Lung Injury or Systemic Side Effects.

Akbal-Dagistan O, Sevim M, Sen L, Basarir N, Culha M, Erturk A Pharmaceutics. 2022; 14(11).

PMID: 36365193 PMC: 9696372. DOI: 10.3390/pharmaceutics14112375.


Pulmonary delivery of favipiravir inhalation solution for COVID-19 treatment: characterization, stability, cytotoxicity, and antiviral activity using real time cell analysis.

Yildiz Pekoz A, Dagistan O, Fael H, Culha M, Erturk A, Basarir N Drug Deliv. 2022; 29(1):2846-2854.

PMID: 36062490 PMC: 9448368. DOI: 10.1080/10717544.2022.2118398.


Antivirals and the Potential Benefits of Orally Inhaled Drug Administration in COVID-19 Treatment.

Sahin G, Akbal-Dagistan O, Culha M, Erturk A, Basarir N, Sancar S J Pharm Sci. 2022; 111(10):2652-2661.

PMID: 35691607 PMC: 9181835. DOI: 10.1016/j.xphs.2022.06.004.


Nanotechnology-Assisted Metered-Dose Inhalers (MDIs) for High-Performance Pulmonary Drug Delivery Applications.

Kumar R, Mehta P, Shankar K, Rajora M, Mishra Y, Mostafavi E Pharm Res. 2022; 39(11):2831-2855.

PMID: 35552983 PMC: 9097569. DOI: 10.1007/s11095-022-03286-y.